#  KOHLER 34455-NA Exhaust Fan Specifications

ENERGY STAR PD #4528864 · Bathroom/Utility Room · Qualified 2026-01-28

Verified Specification Summary

In EPA dataset 8dv7-nngq, KOHLER 34455-NA tests at 130 CFM free discharge (103.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 3.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 103 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34455-NA Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 103.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 79.8% @ 0.25"

- **Motor Draw**: 35.1 W (12.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does KOHLER 34455-NA vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER 34455-NA (EPA filing PD #4528864) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 130 CFM open-air to 103.7 CFM at 0.25 in. w.g. (79.8% retention, 7.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside KOHLER's 32-unit lineup, 34455-NA (series: 34455) carries PD #4528864 dating to 2026-01-28. Lighting kit: Yes. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.1 watts, about 12.8 kWh/yr (~$2.05/yr at $0.16/kWh) for 1 hr/day shower timers or 307.5 kWh/yr (~$49.20/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).

## Why avoid unvented attic termination with KOHLER 34455-NA?

Under ASHRAE 62.2 best practice, KOHLER 34455-NA needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern KOHLER 34455-NA?

Before cutting ceiling drywall or sizing attic transitions for KOHLER 34455-NA, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | KOHLER (32 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 34455-NA / 34455 | PD ID 4528864 (Qualified 2026-01-28) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (103.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit KOHLER 34455-NA?

Bathroom ventilation sizing below maps KOHLER 34455-NA motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for KOHLER 34455-NA

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.8 kWh/yr (~$2.05/yr) | 35.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 307.5 kWh/yr (~$49.20/yr) | 35.1 W x 8,760 hrs / 1,000 |

## What peer models sit nearest KOHLER 34455-NA in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to KOHLER 34455-NA.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| [**Greenheck SP-B110ES**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/) | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| [**KORA SBF110N**](https://siematic-charleston.com/ventilation-fans/kora-sbf110n/) | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |

## What percentage of room demand does KOHLER 34455-NA cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against KOHLER 34455-NA tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying KOHLER 34455-NA?

Match KOHLER 34455-NA directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 103.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around ENERGY STAR sones up to 103 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for KOHLER 34455-NA?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing KOHLER 34455-NA.

### What bathroom square footage can KOHLER 34455-NA ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), KOHLER 34455-NA covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does KOHLER 34455-NA run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with KOHLER 34455-NA.

### What happens to KOHLER 34455-NA CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, KOHLER 34455-NA moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does KOHLER 34455-NA sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, KOHLER 34455-NA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does KOHLER 34455-NA cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running KOHLER 34455-NA 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can KOHLER 34455-NA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34455-NA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing KOHLER 34455-NA?

KOHLER 34455-NA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change KOHLER 34455-NA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34455-NA's safe coverage footprint from 50 sq ft to 44 sq ft.

## What related resources expand on KOHLER 34455-NA?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KOHLER 34456 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34456/)
- [KOHLER 34456-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34456-na/)
- [KOHLER 34455 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34455/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)