title: "KOHLER 34457-NA Bath Fan (130 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/kohler-34457-na-4528856/
description: "ENERGY STAR specs for KOHLER 34457-NA: 130 CFM, 3.7 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  KOHLER 34457-NA Exhaust Fan Specifications

ENERGY STAR PD #4528856 · Bathroom/Utility Room · Qualified 2026-01-28

Verified Specification Summary

The KOHLER 34457-NA (34457) moves 130 CFM at 0.1 in. w.g. (103.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 3.7 CFM/W efficacy, sizing bathrooms up to 103 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34457-NA Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 103.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 79.8% @ 0.25"

- **Motor Draw**: 35.1 W (12.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does KOHLER 34457-NA vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER 34457-NA (EPA filing PD #4528856) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 130 CFM open-air to 103.7 CFM at 0.25 in. w.g. (79.8% retention, 7.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 34457-NA (series: 34457) (PD #4528856) among 32 KOHLER entries qualified through 2026-01-28. Lighting kit: Yes. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.1 watts, about 12.8 kWh/yr (~$2.05/yr at $0.16/kWh) for 1 hr/day shower timers or 307.5 kWh/yr (~$49.20/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).

## How does duct geometry alter KOHLER 34457-NA static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to KOHLER 34457-NA?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for KOHLER 34457-NA alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | KOHLER (32 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 34457-NA / 34457 | PD ID 4528856 (Qualified 2026-01-28) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (103.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can KOHLER 34457-NA ventilate safely?

Sizing outputs below convert KOHLER 34457-NA tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for KOHLER 34457-NA

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.8 kWh/yr (~$2.05/yr) | 35.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 307.5 kWh/yr (~$49.20/yr) | 35.1 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match KOHLER 34457-NA closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| [**Greenheck SP-B110ES**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/) | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| [**KORA SBF110N**](https://siematic-charleston.com/ventilation-fans/kora-sbf110n/) | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |

## Will KOHLER 34457-NA clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether KOHLER 34457-NA satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip KOHLER 34457-NA on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for KOHLER 34457-NA carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 53 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 103 sq ft with 8-ft ceilings (92 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern KOHLER 34457-NA?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting KOHLER 34457-NA.

### How does KOHLER 34457-NA score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), KOHLER 34457-NA delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify KOHLER 34457-NA?

Rule out KOHLER 34457-NA when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke KOHLER 34457-NA capacity?

Because static drag at 0.25 in. w.g. lowers KOHLER 34457-NA from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is KOHLER 34457-NA compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, KOHLER 34457-NA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does KOHLER 34457-NA consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, KOHLER 34457-NA draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can KOHLER 34457-NA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34457-NA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing KOHLER 34457-NA?

KOHLER 34457-NA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change KOHLER 34457-NA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34457-NA's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which guides and calculators connect next to KOHLER 34457-NA?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for KOHLER 34457-NA.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KOHLER K-34454 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34454/)
- [KOHLER K-34454-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34454-na-4528853/)
- [KOHLER 34457 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34457-4439609/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools
