---
title: "KOHLER 34457 Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/kohler-34457/
description: "ENERGY STAR specs for KOHLER 34457: 150 CFM, 4.5 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  KOHLER 34457 Exhaust Fan Specifications

ENERGY STAR PD #4439608 · Bathroom/Utility Room · Qualified 2025-06-20

Verified Specification Summary

Rated for 150 CFM open-air (125.1 CFM at 0.25 in. w.g.), KOHLER 34457 omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 125 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34457 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 125.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.5 CFM/W (#632/1,145)

- **Static Retention**: 83.4% @ 0.25"

- **Motor Draw**: 33.3 W (12.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does KOHLER 34457 vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER 34457 (EPA filing PD #4439608) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 125.1 CFM at 0.25 in. w.g. (83.4% retention, 4.3 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4439608 verifies 34457 (series: ATMO) under KOHLER (32 listed models, qualified 2025-06-20). Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

## How do flex elbows choke KOHLER 34457 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps KOHLER 34457 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does KOHLER 34457 meet residential exhaust fan code specs?

Inspect KOHLER 34457 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | KOHLER (32 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 34457 / ATMO | PD ID 4439608 (Qualified 2025-06-20) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (125.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match KOHLER 34457 airflow output?

Annual electricity figures and room square-footage ceilings below reflect KOHLER 34457 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for KOHLER 34457

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 125 sq ft | 1 CFM/sq ft @ 125.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 111 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 75 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |

## Which competing models share KOHLER 34457 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |

## How much airflow margin does KOHLER 34457 give your bath?

Run a quick local room-volume check for KOHLER 34457 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip KOHLER 34457 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for KOHLER 34457 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 75 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 125 sq ft with 8-ft ceilings (111 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about KOHLER 34457?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to KOHLER 34457.

### What duct and room conditions disqualify KOHLER 34457?

Rule out KOHLER 34457 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke KOHLER 34457 capacity?

Because static drag at 0.25 in. w.g. lowers KOHLER 34457 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is KOHLER 34457 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, KOHLER 34457 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does KOHLER 34457 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, KOHLER 34457 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can KOHLER 34457 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34457's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing KOHLER 34457?

KOHLER 34457 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change KOHLER 34457's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34457's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does KOHLER 34457 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), KOHLER 34457 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## Which GradeMark tools pair best with KOHLER 34457?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to KOHLER 34457.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KOHLER 34457-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34457-na/)
- [KOHLER K-34454 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34454-4528849/)
- [KOHLER 34456-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34456-na-4528843/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
