title: "KOHLER K-34454-NA Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/kohler-k-34454-na/
description: "ENERGY STAR specs for KOHLER K-34454-NA: 150 CFM, 4.4 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  KOHLER K-34454-NA Exhaust Fan Specifications

ENERGY STAR PD #4528852 · Bathroom/Utility Room · Qualified 2026-01-28

Verified Specification Summary

Homeowners specifying KOHLER K-34454-NA gain 150 CFM at 0.1 in. w.g. (126 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.4 CFM/W efficacy, venting bathrooms up to 126 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER K-34454-NA Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 126 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 84.0% @ 0.25"

- **Motor Draw**: 34.1 W (12.4 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does KOHLER K-34454-NA vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER K-34454-NA (EPA filing PD #4528852) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 126 CFM at 0.25 in. w.g. (84.0% retention, 3.7 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: KOHLER registers 32 certified models, with SKU K-34454-NA (series: 34454) (PD #4528852) certified since 2026-01-28. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 34.1 watts, about 12.4 kWh/yr (~$1.98/yr at $0.16/kWh) for 1 hr/day shower timers or 298.7 kWh/yr (~$47.79/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

## Which exterior damper path suits KOHLER K-34454-NA best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around KOHLER K-34454-NA housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do KOHLER K-34454-NA acoustic and static metrics stand?

Compare KOHLER K-34454-NA published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | KOHLER (32 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | K-34454-NA / 34454 | PD ID 4528852 (Qualified 2026-01-28) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (126 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can KOHLER K-34454-NA handle taller ceilings or walk-in tub steam?

Evaluate how KOHLER K-34454-NA scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for KOHLER K-34454-NA

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 126 sq ft | 1 CFM/sq ft @ 126 CFM |
| Tall Bath (9-ft Ceiling) | Up to 112 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 76 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.4 kWh/yr (~$1.98/yr) | 34.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 298.7 kWh/yr (~$47.79/yr) | 34.1 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near KOHLER K-34454-NA?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |

## Is KOHLER K-34454-NA sized right for your shower or tub room?

Check whether KOHLER K-34454-NA clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip KOHLER K-34454-NA on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for KOHLER K-34454-NA carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 76 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 126 CFM net static output
- **Works well for:** Collar pairs with 6 in. diameter duct straight outdoors

## Which code checks and cost facts matter for KOHLER K-34454-NA?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to KOHLER K-34454-NA.

### What duct and room conditions disqualify KOHLER K-34454-NA?

Rule out KOHLER K-34454-NA when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke KOHLER K-34454-NA capacity?

Because static drag at 0.25 in. w.g. lowers KOHLER K-34454-NA from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is KOHLER K-34454-NA compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, KOHLER K-34454-NA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does KOHLER K-34454-NA consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, KOHLER K-34454-NA draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can KOHLER K-34454-NA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER K-34454-NA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing KOHLER K-34454-NA?

KOHLER K-34454-NA features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change KOHLER K-34454-NA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER K-34454-NA's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does KOHLER K-34454-NA score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), KOHLER K-34454-NA delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## How can you cross-check KOHLER K-34454-NA against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for KOHLER K-34454-NA.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KOHLER K-34455 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34455/)
- [KOHLER K-34455-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34455-na/)
- [KOHLER K-34454 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34454-4528849/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)