title: "KOHLER K-34455 Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/kohler-k-34455/
description: "ENERGY STAR specs for KOHLER K-34455: 150 CFM, 4.5 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  KOHLER K-34455 Exhaust Fan Specifications

ENERGY STAR PD #4528861 · Bathroom/Utility Room · Qualified 2026-01-28

Verified Specification Summary

Rated for 150 CFM open-air (125.1 CFM at 0.25 in. w.g.), KOHLER K-34455 omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 125 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER K-34455 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 125.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.5 CFM/W (#632/1,145)

- **Static Retention**: 83.4% @ 0.25"

- **Motor Draw**: 33.3 W (12.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does KOHLER K-34455 vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER K-34455 (EPA filing PD #4528861) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 125.1 CFM at 0.25 in. w.g. (83.4% retention, 4.3 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4528861 verifies K-34455 (series: 34455) under KOHLER (32 listed models, qualified 2026-01-28). Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

## How do flex elbows choke KOHLER K-34455 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps KOHLER K-34455 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does KOHLER K-34455 meet residential exhaust fan code specs?

Inspect KOHLER K-34455 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | KOHLER (32 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | K-34455 / 34455 | PD ID 4528861 (Qualified 2026-01-28) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (125.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match KOHLER K-34455 airflow output?

Annual electricity figures and room square-footage ceilings below reflect KOHLER K-34455 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for KOHLER K-34455

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 125 sq ft | 1 CFM/sq ft @ 125.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 111 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 75 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |

## Which competing models share KOHLER K-34455 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |

## How much airflow margin does KOHLER K-34455 give your bath?

Run a quick local room-volume check for KOHLER K-34455 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does KOHLER K-34455 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering KOHLER K-34455.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 75 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 125 sq ft with 8-ft ceilings (111 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about KOHLER K-34455?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to KOHLER K-34455.

### Will KOHLER K-34455 disturb adjacent bedrooms during night use?

Acoustic measurement places KOHLER K-34455 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running KOHLER K-34455 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of KOHLER K-34455 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can KOHLER K-34455 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER K-34455's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing KOHLER K-34455?

KOHLER K-34455 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change KOHLER K-34455's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER K-34455's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is KOHLER K-34455 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), KOHLER K-34455 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than KOHLER K-34455?

Do not force KOHLER K-34455 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does KOHLER K-34455 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, KOHLER K-34455 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

## Which GradeMark tools pair best with KOHLER K-34455?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to KOHLER K-34455.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KOHLER K-34455-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34455-na/)
- [KOHLER K-34456 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34456-4528847/)
- [KOHLER K-34454-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34454-na/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)