#  KOHLER K-34456-NA Exhaust Fan Specifications

ENERGY STAR PD #4528845 · Bathroom/Utility Room · Qualified 2026-01-28

Verified Specification Summary

In EPA dataset 8dv7-nngq, KOHLER K-34456-NA tests at 150 CFM free discharge (126 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 126 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER K-34456-NA Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 126 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 84.0% @ 0.25"

- **Motor Draw**: 34.1 W (12.4 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does KOHLER K-34456-NA vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER K-34456-NA (EPA filing PD #4528845) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 126 CFM at 0.25 in. w.g. (84.0% retention, 3.7 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside KOHLER's 32-unit lineup, K-34456-NA (series: 34456) carries PD #4528845 dating to 2026-01-28. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 34.1 watts, about 12.4 kWh/yr (~$1.98/yr at $0.16/kWh) for 1 hr/day shower timers or 298.7 kWh/yr (~$47.79/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

## Why avoid unvented attic termination with KOHLER K-34456-NA?

Under ASHRAE 62.2 best practice, KOHLER K-34456-NA needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern KOHLER K-34456-NA?

Before cutting ceiling drywall or sizing attic transitions for KOHLER K-34456-NA, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | KOHLER (32 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | K-34456-NA / 34456 | PD ID 4528845 (Qualified 2026-01-28) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (126 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit KOHLER K-34456-NA?

Bathroom ventilation sizing below maps KOHLER K-34456-NA motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for KOHLER K-34456-NA

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 126 sq ft | 1 CFM/sq ft @ 126 CFM |
| Tall Bath (9-ft Ceiling) | Up to 112 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 76 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.4 kWh/yr (~$1.98/yr) | 34.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 298.7 kWh/yr (~$47.79/yr) | 34.1 W x 8,760 hrs / 1,000 |

## What peer models sit nearest KOHLER K-34456-NA in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to KOHLER K-34456-NA.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |

## What percentage of room demand does KOHLER K-34456-NA cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against KOHLER K-34456-NA tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does KOHLER K-34456-NA fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering KOHLER K-34456-NA.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 126 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 126 sq ft
- **Target scenario:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for KOHLER K-34456-NA?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing KOHLER K-34456-NA.

### Does running KOHLER K-34456-NA continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of KOHLER K-34456-NA draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can KOHLER K-34456-NA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER K-34456-NA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing KOHLER K-34456-NA?

KOHLER K-34456-NA features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change KOHLER K-34456-NA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER K-34456-NA's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is KOHLER K-34456-NA code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), KOHLER K-34456-NA clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than KOHLER K-34456-NA?

Do not force KOHLER K-34456-NA into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does KOHLER K-34456-NA retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, KOHLER K-34456-NA produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

### Will KOHLER K-34456-NA disturb adjacent bedrooms during night use?

Acoustic measurement places KOHLER K-34456-NA at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## What related resources expand on KOHLER K-34456-NA?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KOHLER K-34457 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34457/)
- [KOHLER K-34457-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34457-na/)
- [KOHLER K-34456 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-k-34456-4528847/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)