title: "Loren Cook Company GC-242 Bath Fan (142 CFM, 1.7 Sone)"
url: https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/
description: "ENERGY STAR specs for Loren Cook Company GC-242: 142 CFM, 1.7 sones (#518 of 607), 5.3 CFM/W, 4.5 x 6 in. rectangular and 5 closest peer fans."
---

#  Loren Cook Company GC-242 Exhaust Fan Specifications

ENERGY STAR PD #2250174 · Bathroom/Utility Room · Qualified 2014-11-27

Verified Specification Summary

Certified by EPA ENERGY STAR, Loren Cook Company GC-242 delivers 142 CFM free-air (112 CFM at 0.25 in. w.g.) and registers #518 of 607 in quietness (1.7 sones) and delivers 5.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 112 sq ft (8-ft height) or 99 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Loren Cook Company GC-242 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 142 / 112 CFM

- **Noise @ 0.1"**: 1.7 sones (#518/607)

- **Efficacy Rank**: 5.3 CFM/W (#494/1,145)

- **Static Retention**: 78.9% @ 0.25"

- **Motor Draw**: 26.8 W (9.8 kWh/yr)

- **Duct & Tier**: 4.5 x 6 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Loren Cook Company GC-242 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.7 sones (#518 of 607 rated models, 0.70 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 142 CFM open-air to 112 CFM at 0.25 in. w.g. (78.9% retention, 8.8 pts lower retention than the 87.7% median), making smooth 4.5 x 6 in. rectangular rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Loren Cook Company's 5-unit lineup, GC-242 (series: Gemini, Model GC, 200-900 Series Ceiling and Wall Blowers) carries PD #2250174 dating to 2014-11-27. Lighting kit: No. At 5.3 CFM/W (#494 of 1,145, top 43.5% of 1,145 rated models, more efficient than 56.5% of rated models, 0.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

## How noisy is Loren Cook Company GC-242 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Loren Cook Company GC-242 measures 1.7 sones across the 1,145-model registry.

## Why does rigid 4.5 x 6 in. rectangular ducting protect Loren Cook Company GC-242 airflow?

Connecting Loren Cook Company GC-242 through rigid 4.5 x 6 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Loren Cook Company GC-242 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Loren Cook Company GC-242 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Loren Cook Company (5 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | GC-242 / Gemini, Model GC, 200-900 Series Ceiling and Wall Blowers | PD ID 2250174 (Qualified 2014-11-27) |
| **Duct Connection** | 4.5 x 6 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (112 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Loren Cook Company GC-242?

Calculated coverage metrics translate Loren Cook Company GC-242 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Loren Cook Company GC-242

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.8 kWh/yr (~$1.57/yr) | 26.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 234.8 kWh/yr (~$37.57/yr) | 26.8 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Loren Cook Company GC-242?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones (-0.20) | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones (-0.20) | 4.5 CFM/W | 6 in. diameter |
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones (-0.20) | 4.7 CFM/W | 6 in. diameter |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones (-0.20) | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones (-0.20) | 4.5 CFM/W | 6 in. diameter |

## Does Loren Cook Company GC-242 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Loren Cook Company GC-242 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Loren Cook Company GC-242 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Loren Cook Company GC-242 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 62 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 112 CFM net static output
- **Works well for:** Collar pairs with 4.5 x 6 in. rectangular duct straight outdoors

## Which homeowner questions come up most for Loren Cook Company GC-242?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Loren Cook Company GC-242.

### Will long attic ducting choke Loren Cook Company GC-242 capacity?

Because static drag at 0.25 in. w.g. lowers Loren Cook Company GC-242 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4.5 x 6 in. rectangular rigid ducting straight to a dedicated exterior damper.

### How loud is Loren Cook Company GC-242 compared with a standard 3.0 sone builder fan?

Tested at 1.7 sones, Loren Cook Company GC-242 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Loren Cook Company GC-242 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Loren Cook Company GC-242 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Loren Cook Company GC-242 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Loren Cook Company GC-242's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Loren Cook Company GC-242?

Loren Cook Company GC-242 features a 4.5 x 6 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Loren Cook Company GC-242's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Loren Cook Company GC-242's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Loren Cook Company GC-242 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Loren Cook Company GC-242 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Loren Cook Company GC-242?

Rule out Loren Cook Company GC-242 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## Where can you explore more benchmarks around Loren Cook Company GC-242?

Use the related reference pages and estimators below to cross-check Loren Cook Company GC-242 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Loren Cook Company GCVF 100 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/)
- [Loren Cook Company GCVF 300 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-300/)
- [Air King AK90 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak90/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)