title: "Loren Cook Company GCVF 100 Bath Fan (127 CFM, 1.7 Sone)"
url: https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/
description: "ENERGY STAR specs for Loren Cook Company GCVF 100: 127 CFM, 1.7 sones (#518 of 607), 11.1 CFM/W, 5.94 in. diameter and 5 closest peer fans."
---

#  Loren Cook Company GCVF 100 Exhaust Fan Specifications

ENERGY STAR PD #2340135 · Bathroom/Utility Room · Qualified 2019-01-03

Verified Specification Summary

Certified by EPA ENERGY STAR, Loren Cook Company GCVF 100 delivers 127 CFM free-air (unpublished 0.25 in. w.g. output) and registers #518 of 607 in quietness (1.7 sones) and delivers 11.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 127 sq ft (8-ft height) or 112 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Loren Cook Company GCVF 100 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 127 / N/A CFM

- **Noise @ 0.1"**: 1.7 sones (#518/607)

- **Efficacy Rank**: 11.1 CFM/W (#128/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 11.4 W (4.2 kWh/yr)

- **Duct & Tier**: 5.94 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Loren Cook Company GCVF 100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.7 sones (#518 of 607 rated models, 0.70 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Free-discharge delivery reaches 127 CFM (#286 of 1,145 certified models) via a 5.94 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5.94 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Loren Cook Company registers 5 certified models, with SKU GCVF 100 (series: Gemini, Model GC, VF 100) (PD #2340135) certified since 2019-01-03. Lighting kit: No. At 11.1 CFM/W (#128 of 1,145, top 11.4% of 1,145 rated models, more efficient than 88.6% of rated models, 6.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.4 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 99.9 kWh/yr (~$15.98/yr) continuously. Closest competing matches include Delta SMT130H (130.0 CFM) and Delta SMT130M (130.0 CFM).

## How noisy is Loren Cook Company GCVF 100 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Loren Cook Company GCVF 100 measures 1.7 sones across the 1,145-model registry.

## Why does rigid 5.94 in. diameter ducting protect Loren Cook Company GCVF 100 airflow?

Connecting Loren Cook Company GCVF 100 through rigid 5.94 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Loren Cook Company GCVF 100 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Loren Cook Company GCVF 100 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Loren Cook Company (5 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | GCVF 100 / Gemini, Model GC, VF 100 | PD ID 2340135 (Qualified 2019-01-03) |
| **Duct Connection** | 5.94 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (127 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Loren Cook Company GCVF 100?

Calculated coverage metrics translate Loren Cook Company GCVF 100 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Loren Cook Company GCVF 100

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 127 sq ft | 1 CFM/sq ft @ 127 CFM |
| Tall Bath (9-ft Ceiling) | Up to 112 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 77 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 99.9 kWh/yr (~$15.98/yr) | 11.4 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Loren Cook Company GCVF 100?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta SMT130H**](https://siematic-charleston.com/ventilation-fans/delta-smt130h/) | 130 / 126.3 CFM | Unpublished | 11.4 CFM/W | 6 in. diameter |
| [**Delta SMT130M**](https://siematic-charleston.com/ventilation-fans/delta-smt130m/) | 130 / 126.3 CFM | Unpublished | 11.4 CFM/W | 6 in. diameter |
| [**ACIQ AEPD140-3**](https://siematic-charleston.com/ventilation-fans/aciq-aepd140-3/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| [**CFM TF140-EC**](https://siematic-charleston.com/ventilation-fans/cfm-tf140-ec/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |
| [**Haier QVE110DTWW**](https://siematic-charleston.com/ventilation-fans/haier-qve110dtww/) | 140 / 146.6 CFM | Unpublished | 11.5 CFM/W | 6 in. diameter |

## Does Loren Cook Company GCVF 100 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Loren Cook Company GCVF 100 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Loren Cook Company GCVF 100 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Loren Cook Company GCVF 100 for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 77 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 127 CFM net static output
- **Best application:** Collar pairs with 5.94 in. diameter duct straight outdoors

## Which homeowner questions come up most for Loren Cook Company GCVF 100?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Loren Cook Company GCVF 100.

### Does Loren Cook Company GCVF 100 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Loren Cook Company GCVF 100 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Loren Cook Company GCVF 100 in a bathroom remodel?

Avoid specifying Loren Cook Company GCVF 100 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Loren Cook Company GCVF 100 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Loren Cook Company GCVF 100 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 5.94 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Loren Cook Company GCVF 100 occupy in EPA filings?

With 1.7 sones at 0.1 in. w.g., Loren Cook Company GCVF 100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Loren Cook Company GCVF 100 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Loren Cook Company GCVF 100 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Loren Cook Company GCVF 100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Loren Cook Company GCVF 100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Loren Cook Company GCVF 100?

Loren Cook Company GCVF 100 features a 5.94 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Loren Cook Company GCVF 100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Loren Cook Company GCVF 100's safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Loren Cook Company GCVF 100?

Use the related reference pages and estimators below to cross-check Loren Cook Company GCVF 100 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Loren Cook Company GCVF 300 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-300/)
- [Delta SLM70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm70/)
- [Loren Cook Company GC-242 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)