---
title: "Nektra 33003852 Bath Fan (80 CFM, 0.3 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/nektra-33003852/
description: "ENERGY STAR specs for Nektra 33003852: 80 CFM, 0.3 sones (#24 of 607), 3.6 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Nektra 33003852 Exhaust Fan Specifications

ENERGY STAR PD #4498417 · Bathroom/Utility Room · Qualified 2025-09-05

Verified Specification Summary

Certified by EPA ENERGY STAR, Nektra 33003852 delivers 80 CFM free-air (68.5 CFM at 0.25 in. w.g.) and registers #24 of 607 in quietness (0.3 sones) and delivers 3.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 68 sq ft (8-ft height) or 60 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nektra 33003852 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 68.5 CFM

- **Noise @ 0.1"**: 0.3 sones (#24/607)

- **Efficacy Rank**: 3.6 CFM/W (#1,017/1,145)

- **Static Retention**: 85.6% @ 0.25"

- **Motor Draw**: 22.2 W (8.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Nektra 33003852 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.5 CFM out of 80 CFM (85.6% retention, 2.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Nektra maintains 4 active ENERGY STAR blowers; 33003852 (series: 33003852) (PD #4498417) gained qualification on 2025-09-05. Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include Wintek BPT15B-80H2 (80.0 CFM) and Broan RB80 (80.0 CFM).

## How noisy is Nektra 33003852 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Nektra 33003852 measures 0.3 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Nektra 33003852 airflow?

Connecting Nektra 33003852 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Nektra 33003852 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Nektra 33003852 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Nektra (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 33003852 / 33003852 | PD ID 4498417 (Qualified 2025-09-05) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (68.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Nektra 33003852?

Calculated coverage metrics translate Nektra 33003852 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Nektra 33003852

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 60 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.1 kWh/yr (~$1.30/yr) | 22.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 194.5 kWh/yr (~$31.12/yr) | 22.2 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Nektra 33003852?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Wintek BPT15B-80H2**](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h2/) | 80 / 68.5 CFM | 0.3 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| [**Broan RB80**](https://siematic-charleston.com/ventilation-fans/broan-rb80/) | 80 / 63.1 CFM | 0.3 sones (Same) | 3.0 CFM/W | 4 in. diameter |
| [**Broan RB80L1**](https://siematic-charleston.com/ventilation-fans/broan-rb80l1/) | 80 / 61.2 CFM | 0.3 sones (Same) | 2.9 CFM/W | 4 in. diameter |
| [**VOTATEC VO-FN4W25-AC-80**](https://siematic-charleston.com/ventilation-fans/votatec-vo-fn4w25-ac-80/) | 80 / 66.3 CFM | 0.4 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
| [**Wintek BPT15B-80H1**](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h1/) | 80 / 66.3 CFM | 0.4 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |

## Does Nektra 33003852 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Nektra 33003852 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Nektra 33003852 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Nektra 33003852.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 68.5 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Nektra 33003852?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Nektra 33003852.

### Will Nektra 33003852 disturb adjacent bedrooms during night use?

Acoustic measurement places Nektra 33003852 at 0.3 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Nektra 33003852 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Nektra 33003852 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Nektra 33003852 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nektra 33003852's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Nektra 33003852?

Nektra 33003852 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Nektra 33003852's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nektra 33003852's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Nektra 33003852 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Nektra 33003852 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Nektra 33003852?

Do not force Nektra 33003852 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Nektra 33003852 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Nektra 33003852 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

## Where can you explore more benchmarks around Nektra 33003852?

Use the related reference pages and estimators below to cross-check Nektra 33003852 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Pennbarry ZQ80-4" Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/pennbarry-zq80-4/)
- [Wintek BPT15B-80H2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h2/)
- [Delta SIG80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-sig80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
