title: "Nutone AERN110RGBL Bath Fan (110 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/nutone-aern110rgbl/
description: "ENERGY STAR specs for Nutone AERN110RGBL: 110 CFM, 1.5 sones (#412 of 607), 4.0 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  Nutone AERN110RGBL Exhaust Fan Specifications

ENERGY STAR PD #2339162 · Bathroom/Utility Room · Qualified 2019-05-31

Verified Specification Summary

Tested under HVI protocols, the Nutone AERN110RGBL exhaust unit achieves 110 CFM at 0.1 in. w.g. (97.6 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy, covering standard baths up to 97 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone AERN110RGBL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 97.6 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.0 CFM/W (#847/1,145)

- **Static Retention**: 88.7% @ 0.25"

- **Motor Draw**: 27.5 W (10.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Nutone AERN110RGBL vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.6 CFM out of 110 CFM (88.7% retention, 1.0 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2339162 verifies AERN110RGBL (series: INVENT) under Nutone (16 listed models, qualified 2019-05-31). Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.5 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 240.9 kWh/yr (~$38.54/yr) continuously. Closest competing matches include Commercial Electric 7130-16-CE (110.0 CFM) and Broan AER110RGBL (110.0 CFM).

## Where do Nutone AERN110RGBL sones rank across EPA ENERGY STAR fans?

Comparing Nutone AERN110RGBL (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Nutone AERN110RGBL CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Nutone AERN110RGBL, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Nutone AERN110RGBL measure up on airflow and noise ratings?

Each row below breaks down Nutone AERN110RGBL certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Nutone (16 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AERN110RGBL / INVENT | PD ID 2339162 (Qualified 2019-05-31) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (97.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Nutone AERN110RGBL CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Nutone AERN110RGBL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 97 sq ft | 1 CFM/sq ft @ 97.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 86 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 47 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.0 kWh/yr (~$1.60/yr) | 27.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 240.9 kWh/yr (~$38.54/yr) | 27.5 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Nutone AERN110RGBL?

Compare Nutone AERN110RGBL side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Commercial Electric 7130-16-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7130-16-ce/) | 110 / 103.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Broan AER110RGBL**](https://siematic-charleston.com/ventilation-fans/broan-aer110rgbl/) | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-07-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-07-plus/) | 110 / 91.6 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-25L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-25l-5cct-bl/) | 110 / 91.6 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| [**Akicon AK15110N5-B**](https://siematic-charleston.com/ventilation-fans/akicon-ak15110n5-b/) | 110 / 100.5 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |

## Can you size Nutone AERN110RGBL for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Nutone AERN110RGBL verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Nutone AERN110RGBL?

Match Nutone AERN110RGBL directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 97.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 1.5 sones up to 97 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Nutone AERN110RGBL?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Nutone AERN110RGBL.

### What happens to Nutone AERN110RGBL CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Nutone AERN110RGBL moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Nutone AERN110RGBL sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Nutone AERN110RGBL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Nutone AERN110RGBL cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Nutone AERN110RGBL 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Nutone AERN110RGBL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone AERN110RGBL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Nutone AERN110RGBL?

Nutone AERN110RGBL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Nutone AERN110RGBL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone AERN110RGBL's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Nutone AERN110RGBL ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Nutone AERN110RGBL covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Nutone AERN110RGBL run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Nutone AERN110RGBL.

## What neighboring pages and tools support Nutone AERN110RGBL?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Nutone AERN110RGBL.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Nutone AERN110RGBLC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-aern110rgblc/)
- [Nutone AERN110SLW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-aern110slw/)
- [Nutone AERN110LTW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-aern110ltw/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)