#  Nutone AERN80LWH Exhaust Fan Specifications

ENERGY STAR PD #2339161 · Bathroom/Utility Room · Qualified 2019-04-19

Verified Specification Summary

Homeowners specifying Nutone AERN80LWH gain 80 CFM at 0.1 in. w.g. (59.4 CFM at 0.25 in. w.g.) where it registers #194 of 607 in quietness (0.8 sones) and delivers 3.5 CFM/W efficacy, venting bathrooms up to 59 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone AERN80LWH Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 59.4 CFM

- **Noise @ 0.1"**: 0.8 sones (#194/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 74.2% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Nutone AERN80LWH vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.4 CFM at 0.25 in. w.g. (74.2% retention, 13.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2339161 verifies AERN80LWH (series: DECORATIVE) under Nutone (16 listed models, qualified 2019-04-19). Lighting kit: Yes. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Broan AER80LMB (80.0 CFM) and S&P PC80XP (80.0 CFM).

## What acoustic percentile does Nutone AERN80LWH occupy among 1,145 bath blowers?

Inspect how Nutone AERN80LWH positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Nutone AERN80LWH best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Nutone AERN80LWH housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Nutone AERN80LWH acoustic and static metrics stand?

Compare Nutone AERN80LWH published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Nutone (16 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | AERN80LWH / DECORATIVE | PD ID 2339161 (Qualified 2019-04-19) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (59.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.8 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Can Nutone AERN80LWH handle taller ceilings or walk-in tub steam?

Evaluate how Nutone AERN80LWH scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Nutone AERN80LWH

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 59 sq ft | 1 CFM/sq ft @ 59.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Nutone AERN80LWH?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan AER80LMB**](https://siematic-charleston.com/ventilation-fans/broan-aer80lmb/) | 80 / 59.4 CFM | 0.8 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**S&P PC80XP**](https://siematic-charleston.com/ventilation-fans/s-p-pc80xp/) | 80 / 65.7 CFM | 0.8 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Broan AE80B**](https://siematic-charleston.com/ventilation-fans/broan-ae80b/) | 80 / 60.5 CFM | 0.7 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| [**Broan AE80B = A000HFKT with AE80BF1**](https://siematic-charleston.com/ventilation-fans/broan-ae80b-a000hfkt-with-ae80bf1/) | 80 / 60.5 CFM | 0.7 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| [**Broan AE80B = A000HFKTC WITH AE80BF1**](https://siematic-charleston.com/ventilation-fans/broan-ae80b-a000hfktc-with-ae80bf1/) | 80 / 60.5 CFM | 0.7 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |

## Is Nutone AERN80LWH sized right for your shower or tub room?

Check whether Nutone AERN80LWH clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Nutone AERN80LWH?

Match Nutone AERN80LWH directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 59.4 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Nutone AERN80LWH?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Nutone AERN80LWH.

### What happens to Nutone AERN80LWH CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Nutone AERN80LWH moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Nutone AERN80LWH sit on acoustic comfort for senior homeowners?

Measuring 0.8 sones, Nutone AERN80LWH operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Nutone AERN80LWH cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Nutone AERN80LWH 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Nutone AERN80LWH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone AERN80LWH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Nutone AERN80LWH?

Nutone AERN80LWH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Nutone AERN80LWH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone AERN80LWH's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Nutone AERN80LWH ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Nutone AERN80LWH covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Nutone AERN80LWH run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Nutone AERN80LWH.

## How can you cross-check Nutone AERN80LWH against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Nutone AERN80LWH.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [S&P PC80XP Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pc80xp/)
- [Air King BFQL50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-bfql50/)
- [Nutone AER80LWH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-aer80lwh/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)