#  Nutone LPN80=LP80HwithLPN80F Exhaust Fan Specifications

ENERGY STAR PD #2341169 · Bathroom/Utility Room · Qualified 2015-10-01

Verified Specification Summary

Homeowners specifying Nutone LPN80=LP80HwithLPN80F gain 80 CFM at 0.1 in. w.g. (65.6 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 3.7 CFM/W efficacy, venting bathrooms up to 65 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone LPN80=LP80HwithLPN80F Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 65.6 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 82.0% @ 0.25"

- **Motor Draw**: 21.6 W (7.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Nutone LPN80=LP80HwithLPN80F vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 65.6 CFM at 0.25 in. w.g. (82.0% retention, 5.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places LPN80=LP80HwithLPN80F (series: N/A) (PD #2341169) among 16 Nutone entries qualified through 2015-10-01. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.6 watts, about 7.9 kWh/yr (~$1.26/yr at $0.16/kWh) for 1 hr/day shower timers or 189.2 kWh/yr (~$30.27/yr) continuously. Closest competing matches include Broan EZ80 (80.0 CFM) and Broan LP80 (80.0 CFM).

## What acoustic percentile does Nutone LPN80=LP80HwithLPN80F occupy among 1,145 bath blowers?

Inspect how Nutone LPN80=LP80HwithLPN80F positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Nutone LPN80=LP80HwithLPN80F best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Nutone LPN80=LP80HwithLPN80F housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Nutone LPN80=LP80HwithLPN80F acoustic and static metrics stand?

Compare Nutone LPN80=LP80HwithLPN80F published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Nutone (16 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | LPN80=LP80HwithLPN80F / N/A | PD ID 2341169 (Qualified 2015-10-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (65.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Nutone LPN80=LP80HwithLPN80F handle taller ceilings or walk-in tub steam?

Evaluate how Nutone LPN80=LP80HwithLPN80F scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Nutone LPN80=LP80HwithLPN80F

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 65 sq ft | 1 CFM/sq ft @ 65.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 58 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.9 kWh/yr (~$1.26/yr) | 21.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 189.2 kWh/yr (~$30.27/yr) | 21.6 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Nutone LPN80=LP80HwithLPN80F?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan EZ80**](https://siematic-charleston.com/ventilation-fans/broan-ez80-2248924/) | 80 / 65.6 CFM | 1.0 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| [**Broan LP80**](https://siematic-charleston.com/ventilation-fans/broan-lp80-2248890/) | 80 / 65.6 CFM | 1.0 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| [**Broan LP80=LP80HwithLP80F**](https://siematic-charleston.com/ventilation-fans/broan-lp80-lp80hwithlp80f-2248912/) | 80 / 65.6 CFM | 1.0 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| [**Air King AK80H**](https://siematic-charleston.com/ventilation-fans/air-king-ak80h/) | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| [**Air King AK80LS1**](https://siematic-charleston.com/ventilation-fans/air-king-ak80ls1/) | 80 / 71.4 CFM | 1.0 sones (Same) | 3.8 CFM/W | 4 in. diameter |

## Is Nutone LPN80=LP80HwithLPN80F sized right for your shower or tub room?

Check whether Nutone LPN80=LP80HwithLPN80F clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Nutone LPN80=LP80HwithLPN80F on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Nutone LPN80=LP80HwithLPN80F carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 65.6 CFM net static output
- **Works well for:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Nutone LPN80=LP80HwithLPN80F?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Nutone LPN80=LP80HwithLPN80F.

### How much power does Nutone LPN80=LP80HwithLPN80F consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Nutone LPN80=LP80HwithLPN80F draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Nutone LPN80=LP80HwithLPN80F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone LPN80=LP80HwithLPN80F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Nutone LPN80=LP80HwithLPN80F?

Nutone LPN80=LP80HwithLPN80F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Nutone LPN80=LP80HwithLPN80F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone LPN80=LP80HwithLPN80F's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Nutone LPN80=LP80HwithLPN80F score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Nutone LPN80=LP80HwithLPN80F delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Nutone LPN80=LP80HwithLPN80F?

Rule out Nutone LPN80=LP80HwithLPN80F when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Nutone LPN80=LP80HwithLPN80F capacity?

Because static drag at 0.25 in. w.g. lowers Nutone LPN80=LP80HwithLPN80F from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Nutone LPN80=LP80HwithLPN80F compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, Nutone LPN80=LP80HwithLPN80F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

## How can you cross-check Nutone LPN80=LP80HwithLPN80F against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Nutone LPN80=LP80HwithLPN80F.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-08VRE2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-08vre2/)
- [QuFresh BQ80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/qufresh-bq80/)
- [HomeWerks Worldwide 7141-80-RGB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-rgb/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)