Tested under HVI protocols, the Nutone QTN130LE1 exhaust unit achieves 130 CFM at 0.1 in. w.g. (112.7 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 112 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone QTN130LE1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 112.7 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 86.7% @ 0.25"

- **Motor Draw**: 33.3 W (12.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Nutone QTN130LE1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.7 CFM out of 130 CFM (86.7% retention, 1.0 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Nutone registers 16 certified models, with SKU QTN130LE1 (series: QT SERIES) (PD #2404746) certified since 2022-11-18. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and KOHLER 34454 (130.0 CFM).

## Where do Nutone QTN130LE1 sones rank across EPA ENERGY STAR fans?

Comparing Nutone QTN130LE1 (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Nutone QTN130LE1 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Nutone QTN130LE1, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Nutone QTN130LE1 measure up on airflow and noise ratings?

Each row below breaks down Nutone QTN130LE1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Nutone (16 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | QTN130LE1 / QT SERIES | PD ID 2404746 (Qualified 2022-11-18) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (112.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Nutone QTN130LE1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Nutone QTN130LE1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Nutone QTN130LE1?

Compare Nutone QTN130LE1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le/) | 130 / 112.7 CFM | 2.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| [**KOHLER 34454**](https://siematic-charleston.com/ventilation-fans/kohler-34454/) | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |
| [**KOHLER 34454-NA**](https://siematic-charleston.com/ventilation-fans/kohler-34454-na/) | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |
| [**KOHLER 34456**](https://siematic-charleston.com/ventilation-fans/kohler-34456/) | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |
| [**KOHLER 34456-NA**](https://siematic-charleston.com/ventilation-fans/kohler-34456-na/) | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |

## Can you size Nutone QTN130LE1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Nutone QTN130LE1 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Nutone QTN130LE1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Nutone QTN130LE1 for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 112.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around 2.0 sones up to 112 sq ft
- **Best application:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Nutone QTN130LE1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Nutone QTN130LE1.

### Does Nutone QTN130LE1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Nutone QTN130LE1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Nutone QTN130LE1 in a bathroom remodel?

Avoid specifying Nutone QTN130LE1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Nutone QTN130LE1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Nutone QTN130LE1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Nutone QTN130LE1 occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., Nutone QTN130LE1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Nutone QTN130LE1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Nutone QTN130LE1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Nutone QTN130LE1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone QTN130LE1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Nutone QTN130LE1?

Nutone QTN130LE1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Nutone QTN130LE1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone QTN130LE1's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Nutone QTN130LE1?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Nutone QTN130LE1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Akicon AK13110N4-B Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak13110n4-b/)
- [Akicon AK13110N4-S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak13110n4-s/)
- [Delta VFB25AEH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-vfb25aeh/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)