#  OREiN OL1700376 Exhaust Fan Specifications

ENERGY STAR PD #3417435 · Bathroom/Utility Room · Qualified 2024-02-16

Verified Specification Summary

Certified by EPA ENERGY STAR, OREiN OL1700376 delivers 160 CFM free-air (152 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 4.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 152 sq ft (8-ft height) or 135 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside OREiN OL1700376 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 160 / 152 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 4.8 CFM/W (#534/1,145)

- **Static Retention**: 95.0% @ 0.25"

- **Motor Draw**: 33.3 W (12.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does OREiN OL1700376 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 152 CFM out of 160 CFM (95.0% retention, 7.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: OREiN registers 1 certified model, with SKU OL1700376 (series: M071 160CFM OL17003-CCT-US) (PD #3417435) certified since 2024-02-16. Lighting kit: Yes. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Tech Drive TD-BF-19 (160.0 CFM) and VENTECHLATION VF-BF-06 (160.0 CFM).

## How noisy is OREiN OL1700376 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while OREiN OL1700376 measures 1.0 sones across the 1,145-model registry.

## Why does rigid 6 in. diameter ducting protect OREiN OL1700376 airflow?

Connecting OREiN OL1700376 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify OREiN OL1700376 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for OREiN OL1700376 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | OREiN (1 model) | ENERGY STAR Certified Partner |
| **Model Number & Series** | OL1700376 / M071 160CFM OL17003-CCT-US | PD ID 3417435 (Qualified 2024-02-16) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (152 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit OREiN OL1700376?

Calculated coverage metrics translate OREiN OL1700376 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for OREiN OL1700376

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 152 sq ft | 1 CFM/sq ft @ 152 CFM |
| Tall Bath (9-ft Ceiling) | Up to 135 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 102 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to OREiN OL1700376?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-19**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-19/) | 160 / 138.2 CFM | 1.0 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| [**VENTECHLATION VF-BF-06**](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-06/) | 160 / 138.2 CFM | 1.0 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| [**Air King AK150LS**](https://siematic-charleston.com/ventilation-fans/air-king-ak150ls/) | 150 / 124.4 CFM | 0.9 sones (-0.10) | 4.5 CFM/W | 6 in. diameter |
| [**Hampton Bay 7136-02**](https://siematic-charleston.com/ventilation-fans/hampton-bay-7136-02/) | 140 / 124.4 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| [**HomeWerks Worldwide 7136-02HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7136-02hw/) | 140 / 124.4 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |

## Does OREiN OL1700376 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check OREiN OL1700376 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip OREiN OL1700376 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for OREiN OL1700376 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 102 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 152 CFM net static output
- **Works well for:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for OREiN OL1700376?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around OREiN OL1700376.

### How loud is OREiN OL1700376 compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, OREiN OL1700376 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does OREiN OL1700376 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, OREiN OL1700376 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can OREiN OL1700376 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from OREiN OL1700376's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing OREiN OL1700376?

OREiN OL1700376 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change OREiN OL1700376's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing OREiN OL1700376's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does OREiN OL1700376 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), OREiN OL1700376 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify OREiN OL1700376?

Rule out OREiN OL1700376 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke OREiN OL1700376 capacity?

Because static drag at 0.25 in. w.g. lowers OREiN OL1700376 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

## Where can you explore more benchmarks around OREiN OL1700376?

Use the related reference pages and estimators below to cross-check OREiN OL1700376 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Tech Drive TD-BF-19 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-19/)
- [VENTECHLATION VF-BF-06 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-06/)
- [Delta PRO200 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-pro200/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)