title: "Ortech OD-1209PB Bath Fan (120 CFM, 0.9 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/ortech-od-1209pb/
description: "ENERGY STAR specs for Ortech OD-1209PB: 120 CFM, 0.9 sones (#239 of 607), 4.3 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Ortech OD-1209PB Exhaust Fan Specifications

ENERGY STAR PD #2402465 · Bathroom/Utility Room · Qualified 2022-10-07

Verified Specification Summary

Rated for 120 CFM open-air (101.6 CFM at 0.25 in. w.g.), Ortech OD-1209PB registers #239 of 607 in quietness (0.9 sones) and delivers 4.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 101 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OD-1209PB Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 120 / 101.6 CFM

- **Noise @ 0.1"**: 0.9 sones (#239/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 84.7% @ 0.25"

- **Motor Draw**: 27.9 W (10.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech OD-1209PB vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 120 CFM open-air to 101.6 CFM at 0.25 in. w.g. (84.7% retention, 3.0 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Ortech registers 27 certified models, with SKU OD-1209PB (series: OD) (PD #2402465) certified since 2022-10-07. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.9 watts, about 10.2 kWh/yr (~$1.63/yr at $0.16/kWh) for 1 hr/day shower timers or 244.4 kWh/yr (~$39.10/yr) continuously. Closest competing matches include Cyclone ESCBP110 (110.0 CFM) and ACIQ AEP110 (110.0 CFM).

## How does Ortech OD-1209PB acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Ortech OD-1209PB (0.9 sones).

## How do flex elbows choke Ortech OD-1209PB at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Ortech OD-1209PB moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Ortech OD-1209PB meet residential exhaust fan code specs?

Inspect Ortech OD-1209PB mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | OD-1209PB / OD | PD ID 2402465 (Qualified 2022-10-07) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (101.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.9 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Ortech OD-1209PB airflow output?

Annual electricity figures and room square-footage ceilings below reflect Ortech OD-1209PB tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Ortech OD-1209PB

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 101 sq ft | 1 CFM/sq ft @ 101.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 90 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 51 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.2 kWh/yr (~$1.63/yr) | 27.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 244.4 kWh/yr (~$39.10/yr) | 27.9 W x 8,760 hrs / 1,000 |

## Which competing models share Ortech OD-1209PB airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Cyclone ESCBP110**](https://siematic-charleston.com/ventilation-fans/cyclone-escbp110/) | 110 / 101.6 CFM | 0.9 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| [**ACIQ AEP110**](https://siematic-charleston.com/ventilation-fans/aciq-aep110/) | 110 / 94.2 CFM | 0.9 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| [**AERO PURE ABF110L6W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110l6w/) | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AUPU AV11AL3**](https://siematic-charleston.com/ventilation-fans/aupu-av11al3/) | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**Canarm CEP110**](https://siematic-charleston.com/ventilation-fans/canarm-cep110/) | 110 / 94.2 CFM | 0.9 sones (Same) | 4.2 CFM/W | 6 in. diameter |

## How much airflow margin does Ortech OD-1209PB give your bath?

Run a quick local room-volume check for Ortech OD-1209PB by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Ortech OD-1209PB in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Ortech OD-1209PB for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 51 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 101 sq ft with 8-ft ceilings (90 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about Ortech OD-1209PB?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Ortech OD-1209PB.

### Does Ortech OD-1209PB satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Ortech OD-1209PB clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Ortech OD-1209PB undersized or poorly matched for a bath renovation?

Skip Ortech OD-1209PB if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Ortech OD-1209PB CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Ortech OD-1209PB registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Ortech OD-1209PB sound output compare to noisy contractor-grade fans?

Rated at 0.9 sones, Ortech OD-1209PB operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Ortech OD-1209PB?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Ortech OD-1209PB pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OD-1209PB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech OD-1209PB?

Ortech OD-1209PB features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech OD-1209PB's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OD-1209PB's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with Ortech OD-1209PB?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Ortech OD-1209PB.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [ACIQ AEP110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-aep110/)
- [AERO PURE ABF110G15W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110g15w/)
- [Air King AK150LS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak150ls/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)