title: "Ortech OD-9005PB Bath Fan (90 CFM, 0.7 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/ortech-od-9005pb/
description: "ENERGY STAR specs for Ortech OD-9005PB: 90 CFM, 0.7 sones (#135 of 607), 4.2 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency."
---

#  Ortech OD-9005PB Exhaust Fan Specifications

ENERGY STAR PD #4480906 · Bathroom/Utility Room · Qualified 2025-06-20

Verified Specification Summary

Homeowners specifying Ortech OD-9005PB gain 90 CFM at 0.1 in. w.g. (70.9 CFM at 0.25 in. w.g.) where it registers #135 of 607 in quietness (0.7 sones) and delivers 4.2 CFM/W efficacy, venting bathrooms up to 70 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OD-9005PB Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 70.9 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 78.8% @ 0.25"

- **Motor Draw**: 21.4 W (7.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech OD-9005PB vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 70.9 CFM at 0.25 in. w.g. (78.8% retention, 8.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Ortech maintains 27 active ENERGY STAR blowers; OD-9005PB (series: OD-PB) (PD #4480906) gained qualification on 2025-06-20. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include S&P PC80XP (90.0 CFM) and Dayton 5AE68B (90.0 CFM).

## What acoustic percentile does Ortech OD-9005PB occupy among 1,145 bath blowers?

Inspect how Ortech OD-9005PB positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Ortech OD-9005PB best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Ortech OD-9005PB housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Ortech OD-9005PB acoustic and static metrics stand?

Compare Ortech OD-9005PB published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | OD-9005PB / OD-PB | PD ID 4480906 (Qualified 2025-06-20) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (70.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Ortech OD-9005PB handle taller ceilings or walk-in tub steam?

Evaluate how Ortech OD-9005PB scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Ortech OD-9005PB

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.8 kWh/yr (~$1.25/yr) | 21.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 187.5 kWh/yr (~$30.00/yr) | 21.4 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Ortech OD-9005PB?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**S&P PC80XP**](https://siematic-charleston.com/ventilation-fans/s-p-pc80xp-3626825/) | 90 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| [**Dayton 5AE68B**](https://siematic-charleston.com/ventilation-fans/dayton-5ae68b/) | 90 / N/A CFM | 0.8 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| [**Greenheck SP-B90**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b90/) | 90 / 72 CFM | 0.8 sones (+0.10) | 4.3 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-11-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11-plus/) | 90 / 79.5 CFM | 0.8 sones (+0.10) | 4.4 CFM/W | 4 in. diameter |
| [**Air King AK90LS6**](https://siematic-charleston.com/ventilation-fans/air-king-ak90ls6/) | 90 / 72.7 CFM | 0.8 sones (+0.10) | 4.5 CFM/W | 6 in. diameter |

## Is Ortech OD-9005PB sized right for your shower or tub room?

Check whether Ortech OD-9005PB clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Ortech OD-9005PB suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Ortech OD-9005PB for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 20 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 70.9 CFM net static output
- **Best application:** Collar pairs with 6 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Ortech OD-9005PB?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Ortech OD-9005PB.

### Does duct resistance cut Ortech OD-9005PB airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Ortech OD-9005PB achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Ortech OD-9005PB occupy in EPA filings?

With 0.7 sones at 0.1 in. w.g., Ortech OD-9005PB operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

### How many kWh per year does Ortech OD-9005PB add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Ortech OD-9005PB averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Ortech OD-9005PB pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OD-9005PB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech OD-9005PB?

Ortech OD-9005PB features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech OD-9005PB's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OD-9005PB's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Ortech OD-9005PB pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Ortech OD-9005PB easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Ortech OD-9005PB in a bathroom remodel?

Avoid specifying Ortech OD-9005PB in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

## How can you cross-check Ortech OD-9005PB against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Ortech OD-9005PB.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [S&P PC80XP Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pc80xp-3626825/)
- [ACIQ AEP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-aep80/)
- [KORA SBF90DC-MS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kora-sbf90dc-ms/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)