#  Ortech ODC-1109 Exhaust Fan Specifications

ENERGY STAR PD #3892186 · Bathroom/Utility Room · Qualified 2024-12-20

Verified Specification Summary

Certified by EPA ENERGY STAR, Ortech ODC-1109 delivers 116 CFM free-air (106.8 CFM at 0.25 in. w.g.) and registers #357 of 607 in quietness (1.1 sones) and delivers 4.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 106 sq ft (8-ft height) or 94 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODC-1109 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 116 / 106.8 CFM

- **Noise @ 0.1"**: 1.1 sones (#357/607)

- **Efficacy Rank**: 4.7 CFM/W (#545/1,145)

- **Static Retention**: 92.1% @ 0.25"

- **Motor Draw**: 24.7 W (9.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech ODC-1109 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.8 CFM out of 116 CFM (92.1% retention, 4.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3892186 verifies ODC-1109 (series: ODC-1109) under Ortech (27 listed models, qualified 2024-12-20). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 24.7 watts, about 9.0 kWh/yr (~$1.44/yr at $0.16/kWh) for 1 hr/day shower timers or 216.4 kWh/yr (~$34.62/yr) continuously. Closest competing matches include Loren Cook Company GC-222 (115.0 CFM) and Aria QBV01100 (110.0 CFM).

## How noisy is Ortech ODC-1109 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODC-1109 measures 1.1 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Ortech ODC-1109 airflow?

Connecting Ortech ODC-1109 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Ortech ODC-1109 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODC-1109 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ODC-1109 / ODC-1109 | PD ID 3892186 (Qualified 2024-12-20) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.1 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Ortech ODC-1109?

Calculated coverage metrics translate Ortech ODC-1109 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Ortech ODC-1109

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.0 kWh/yr (~$1.44/yr) | 24.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 216.4 kWh/yr (~$34.62/yr) | 24.7 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Ortech ODC-1109?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Loren Cook Company GC-222**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-222/) | 115 / 85 CFM | 1.2 sones (+0.10) | 4.8 CFM/W | 4.5 x 6 in. rectangular |
| [**Aria QBV01100**](https://siematic-charleston.com/ventilation-fans/aria-qbv01100/) | 110 / 101.5 CFM | 1.1 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**Good Housekeeping 84006**](https://siematic-charleston.com/ventilation-fans/good-housekeeping-84006/) | 110 / 101.5 CFM | 1.1 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| [**AERO PURE ABF110G16W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110g16w/) | 110 / 83.6 CFM | 1.1 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AUPU AV11A3**](https://siematic-charleston.com/ventilation-fans/aupu-av11a3/) | 110 / 83.6 CFM | 1.1 sones (Same) | 4.4 CFM/W | 4 in. diameter |

## Does Ortech ODC-1109 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODC-1109 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Ortech ODC-1109?

Compare where Ortech ODC-1109 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 56 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 106.8 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Ortech ODC-1109?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODC-1109.

### How does Ortech ODC-1109 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Ortech ODC-1109 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Ortech ODC-1109 quiet enough for a primary bedroom bathroom?

At 1.1 sones, Ortech ODC-1109 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Ortech ODC-1109 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Ortech ODC-1109 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODC-1109's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech ODC-1109?

Ortech ODC-1109 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech ODC-1109's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODC-1109's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Ortech ODC-1109 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Ortech ODC-1109 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Ortech ODC-1109 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Ortech ODC-1109 lacks adequate reserve.

## Where can you explore more benchmarks around Ortech ODC-1109?

Use the related reference pages and estimators below to cross-check Ortech ODC-1109 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [AERO PURE ABF110G16W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110g16w/)
- [Air King AK110LS6 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak110ls6/)
- [VOTATEC VO-FN4W18-AC-50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/votatec-vo-fn4w18-ac-50/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)