title: "Ortech ODC-9006 Bath Fan (90 CFM, 0.6 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/ortech-odc-9006/
description: "ENERGY STAR specs for Ortech ODC-9006: 90 CFM, 0.6 sones (#107 of 607), 5.6 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Ortech ODC-9006 Exhaust Fan Specifications

ENERGY STAR PD #3892190 · Bathroom/Utility Room · Qualified 2024-12-20

Verified Specification Summary

The Ortech ODC-9006 (OFC-9006) moves 90 CFM at 0.1 in. w.g. (73.4 CFM at 0.25 in. w.g.), registers #107 of 607 in quietness (0.6 sones), and delivers 5.6 CFM/W efficacy, sizing bathrooms up to 73 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODC-9006 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 73.4 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 5.6 CFM/W (#470/1,145)

- **Static Retention**: 81.6% @ 0.25"

- **Motor Draw**: 16.1 W (5.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech ODC-9006 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 73.4 CFM at 0.25 in. w.g. (81.6% retention, 6.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3892190 verifies ODC-9006 (series: OFC-9006) under Ortech (27 listed models, qualified 2024-12-20). Lighting kit: No. At 5.6 CFM/W (#470 of 1,145, top 41.0% of 1,145 rated models, more efficient than 59.0% of rated models, 0.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.1 watts, about 5.9 kWh/yr (~$0.94/yr at $0.16/kWh) for 1 hr/day shower timers or 141.0 kWh/yr (~$22.56/yr) continuously. Closest competing matches include ACIQ ANP80 (80.0 CFM) and Anzzi EF-AZ101WH (80.0 CFM).

## Where does Ortech ODC-9006 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.6 sones against all 1,145 EPA listings.

## How does duct geometry alter Ortech ODC-9006 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Ortech ODC-9006?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Ortech ODC-9006 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ODC-9006 / OFC-9006 | PD ID 3892190 (Qualified 2024-12-20) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (73.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Ortech ODC-9006 ventilate safely?

Sizing outputs below convert Ortech ODC-9006 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Ortech ODC-9006

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 73 sq ft | 1 CFM/sq ft @ 73.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 65 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 23 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.9 kWh/yr (~$0.94/yr) | 16.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 141.0 kWh/yr (~$22.56/yr) | 16.1 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Ortech ODC-9006 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ ANP80**](https://siematic-charleston.com/ventilation-fans/aciq-anp80/) | 80 / 62.6 CFM | 0.6 sones (Same) | 4.9 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ101WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az101wh/) | 80 / 68.9 CFM | 0.7 sones (+0.10) | 5.3 CFM/W | 4 in. diameter |
| [**Aria QBV0800**](https://siematic-charleston.com/ventilation-fans/aria-qbv0800/) | 80 / 68.9 CFM | 0.7 sones (+0.10) | 5.3 CFM/W | 4 in. diameter |
| [**Haier QVE801DTWW**](https://siematic-charleston.com/ventilation-fans/haier-qve801dtww/) | 80 / 68.9 CFM | 0.7 sones (+0.10) | 5.3 CFM/W | 4 in. diameter |
| [**Dayton 3DPE4B**](https://siematic-charleston.com/ventilation-fans/dayton-3dpe4b/) | 90 / N/A CFM | 0.4 sones (-0.20) | 5.5 CFM/W | 6 in. diameter |

## Will Ortech ODC-9006 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Ortech ODC-9006 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Ortech ODC-9006 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Ortech ODC-9006 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 23 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 73 sq ft with 8-ft ceilings (65 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Ortech ODC-9006?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Ortech ODC-9006.

### How loud is Ortech ODC-9006 compared with a standard 3.0 sone builder fan?

Tested at 0.6 sones, Ortech ODC-9006 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Ortech ODC-9006 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Ortech ODC-9006 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Ortech ODC-9006 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODC-9006's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech ODC-9006?

Ortech ODC-9006 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech ODC-9006's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODC-9006's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Ortech ODC-9006 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Ortech ODC-9006 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Ortech ODC-9006?

Rule out Ortech ODC-9006 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Ortech ODC-9006 capacity?

Because static drag at 0.25 in. w.g. lowers Ortech ODC-9006 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

## Which guides and calculators connect next to Ortech ODC-9006?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Ortech ODC-9006.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [ACIQ ANP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-anp80/)
- [AERO PURE ABF80L5OR Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf80l5or/)
- [Broan AE50=HPIVFNwithAE50F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ae50-hpivfnwithae50f/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)