title: "Ortech ODD-70-1 Bath Fan (75 CFM, 0.4 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/ortech-odd-70-1/
description: "ENERGY STAR specs for Ortech ODD-70-1: 75 CFM, 0.4 sones (#50 of 607), 16.7 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Ortech ODD-70-1 Exhaust Fan Specifications

ENERGY STAR PD #3557061 · Bathroom/Utility Room · Qualified 2024-08-02

Verified Specification Summary

In EPA dataset 8dv7-nngq, Ortech ODD-70-1 tests at 75 CFM free discharge (62.3 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 16.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 62 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-70-1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 75 / 62.3 CFM

- **Noise @ 0.1"**: 0.4 sones (#50/607)

- **Efficacy Rank**: 16.7 CFM/W (#1/1,145)

- **Static Retention**: 83.1% @ 0.25"

- **Motor Draw**: 4.5 W (1.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech ODD-70-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 75 CFM open-air to 62.3 CFM at 0.25 in. w.g. (83.1% retention, 4.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places ODD-70-1 (series: ODD-70-1) (PD #3557061) among 27 Ortech entries qualified through 2024-08-02. Lighting kit: No. At 16.7 CFM/W (#1 of 1,145, top 0.3% of 1,145 rated models, more efficient than 99.7% of rated models, 12.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.5 watts, about 1.6 kWh/yr (~$0.26/yr at $0.16/kWh) for 1 hr/day shower timers or 39.4 kWh/yr (~$6.30/yr) continuously. Closest competing matches include DewStop - Breeze Easy BES80 (80.0 CFM) and DewStop - Breeze Easy BEL80 (80.0 CFM).

## Does Ortech ODD-70-1 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Ortech ODD-70-1 at 0.4 sones.

## Why avoid unvented attic termination with Ortech ODD-70-1?

Under ASHRAE 62.2 best practice, Ortech ODD-70-1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Ortech ODD-70-1?

Before cutting ceiling drywall or sizing attic transitions for Ortech ODD-70-1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ODD-70-1 / ODD-70-1 | PD ID 3557061 (Qualified 2024-08-02) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (62.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.4 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Ortech ODD-70-1?

Bathroom ventilation sizing below maps Ortech ODD-70-1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Ortech ODD-70-1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 62 sq ft | 1 CFM/sq ft @ 62.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 55 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 1.6 kWh/yr (~$0.26/yr) | 4.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 39.4 kWh/yr (~$6.30/yr) | 4.5 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Ortech ODD-70-1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Ortech ODD-70-1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**DewStop - Breeze Easy BES80**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bes80/) | 80 / 84.9 CFM | 0.3 sones (-0.10) | 16.1 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL80**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel80/) | 80 / 86.6 CFM | 0.4 sones (Same) | 15.7 CFM/W | 4 in. diameter |
| [**Broan XB80**](https://siematic-charleston.com/ventilation-fans/broan-xb80/) | 80 / 80 CFM | 0.3 sones (-0.10) | 13.8 CFM/W | 6 in. diameter |
| [**Broan XB80=XB00HwithXB80F**](https://siematic-charleston.com/ventilation-fans/broan-xb80-xb00hwithxb80f/) | 80 / 80 CFM | 0.1 sones (-0.30) | 13.8 CFM/W | 6 in. diameter |
| [**Revent RVS80**](https://siematic-charleston.com/ventilation-fans/revent-rvs80/) | 80 / 88.8 CFM | 0.6 sones (+0.20) | 12.6 CFM/W | 4 in. diameter |

## What percentage of room demand does Ortech ODD-70-1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Ortech ODD-70-1 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Ortech ODD-70-1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Ortech ODD-70-1 for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 62.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 0.4 sones up to 62 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Ortech ODD-70-1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Ortech ODD-70-1.

### Why check Ortech ODD-70-1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Ortech ODD-70-1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Ortech ODD-70-1 sound output compare to noisy contractor-grade fans?

Rated at 0.4 sones, Ortech ODD-70-1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Ortech ODD-70-1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Ortech ODD-70-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-70-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech ODD-70-1?

Ortech ODD-70-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech ODD-70-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-70-1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Ortech ODD-70-1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Ortech ODD-70-1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Ortech ODD-70-1 undersized or poorly matched for a bath renovation?

Skip Ortech ODD-70-1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## What related resources expand on Ortech ODD-70-1?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVS80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvs80/)
- [Revent RVSH80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsh80/)
- [DewStop - Breeze Easy BEL80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)