#  Ortech ODD-90-1 Exhaust Fan Specifications

ENERGY STAR PD #3557062 · Bathroom/Utility Room · Qualified 2024-08-02

Verified Specification Summary

Certified by EPA ENERGY STAR, Ortech ODD-90-1 delivers 95 CFM free-air (78.9 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 13.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 78 sq ft (8-ft height) or 70 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-90-1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 95 / 78.9 CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 13.2 CFM/W (#49/1,145)

- **Static Retention**: 83.1% @ 0.25"

- **Motor Draw**: 7.2 W (2.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech ODD-90-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 95 CFM open-air to 78.9 CFM at 0.25 in. w.g. (83.1% retention, 4.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places ODD-90-1 (series: ODD-90-1) (PD #3557062) among 27 Ortech entries qualified through 2024-08-02. Lighting kit: No. At 13.2 CFM/W (#49 of 1,145, top 4.5% of 1,145 rated models, more efficient than 95.5% of rated models, 8.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.2 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 63.1 kWh/yr (~$10.10/yr) continuously. Closest competing matches include Revent RVS80 (80.0 CFM) and Revent RVSH80 (80.0 CFM).

## How noisy is Ortech ODD-90-1 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODD-90-1 measures 0.7 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Ortech ODD-90-1 airflow?

Connecting Ortech ODD-90-1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Ortech ODD-90-1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODD-90-1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ODD-90-1 / ODD-90-1 | PD ID 3557062 (Qualified 2024-08-02) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (78.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Ortech ODD-90-1?

Calculated coverage metrics translate Ortech ODD-90-1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Ortech ODD-90-1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 78 sq ft | 1 CFM/sq ft @ 78.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 28 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.6 kWh/yr (~$0.42/yr) | 7.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 63.1 kWh/yr (~$10.10/yr) | 7.2 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Ortech ODD-90-1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Revent RVS80**](https://siematic-charleston.com/ventilation-fans/revent-rvs80/) | 80 / 88.8 CFM | 0.6 sones (-0.10) | 12.6 CFM/W | 4 in. diameter |
| [**Revent RVSH80**](https://siematic-charleston.com/ventilation-fans/revent-rvsh80/) | 80 / 88.8 CFM | 0.6 sones (-0.10) | 12.6 CFM/W | 4 in. diameter |
| [**Revent RVS110**](https://siematic-charleston.com/ventilation-fans/revent-rvs110/) | 110 / 119.2 CFM | 0.8 sones (+0.10) | 12.3 CFM/W | 4 in. diameter |
| [**Revent RVSH110**](https://siematic-charleston.com/ventilation-fans/revent-rvsh110/) | 110 / 119.2 CFM | 0.8 sones (+0.10) | 12.3 CFM/W | 4 in. diameter |
| [**Revent RVL80**](https://siematic-charleston.com/ventilation-fans/revent-rvl80/) | 80 / 89 CFM | 0.8 sones (+0.10) | 12.0 CFM/W | 4 in. diameter |

## Does Ortech ODD-90-1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODD-90-1 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Ortech ODD-90-1?

Compare where Ortech ODD-90-1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 28 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 78.9 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Ortech ODD-90-1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODD-90-1.

### How does Ortech ODD-90-1 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Ortech ODD-90-1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Ortech ODD-90-1 quiet enough for a primary bedroom bathroom?

At 0.7 sones, Ortech ODD-90-1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Ortech ODD-90-1 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Ortech ODD-90-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-90-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech ODD-90-1?

Ortech ODD-90-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech ODD-90-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-90-1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Ortech ODD-90-1 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Ortech ODD-90-1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Ortech ODD-90-1 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Ortech ODD-90-1 lacks adequate reserve.

## Where can you explore more benchmarks around Ortech ODD-90-1?

Use the related reference pages and estimators below to cross-check Ortech ODD-90-1 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta 50F-LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-50f-led/)
- [Delta ITG50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg50/)
- [Revent RVSH80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsh80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)