title: "Ortech ODDIN-300 Bath Fan (300 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/ortech-oddin-300/
description: "ENERGY STAR specs for Ortech ODDIN-300: 300 CFM, 4.9 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Ortech ODDIN-300 Exhaust Fan Specifications

ENERGY STAR PD #4656694 · In-line (single-port) · Qualified 2026-04-22

Verified Specification Summary

In EPA dataset 8dv7-nngq, Ortech ODDIN-300 tests at 300 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 300 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODDIN-300 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 300 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.9 CFM/W (#519/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 61.2 W (22.3 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech ODDIN-300 vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech ODDIN-300 (EPA filing PD #4656694) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 300 CFM (#16 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Ortech registers 27 certified models, with SKU ODDIN-300 (series: ODDIN) (PD #4656694) certified since 2026-04-22. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 61.2 watts, about 22.3 kWh/yr (~$3.57/yr at $0.16/kWh) for 1 hr/day shower timers or 536.1 kWh/yr (~$85.78/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

## Why avoid unvented attic termination with Ortech ODDIN-300?

Under ASHRAE 62.2 best practice, Ortech ODDIN-300 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Ortech ODDIN-300?

Before cutting ceiling drywall or sizing attic transitions for Ortech ODDIN-300, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ODDIN-300 / ODDIN | PD ID 4656694 (Qualified 2026-04-22) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (300 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Ortech ODDIN-300?

Bathroom ventilation sizing below maps Ortech ODDIN-300 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Ortech ODDIN-300

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 300 sq ft | 1 CFM/sq ft @ 300 CFM |
| Tall Bath (9-ft Ceiling) | Up to 266 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 250 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 22.3 kWh/yr (~$3.57/yr) | 61.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 536.1 kWh/yr (~$85.78/yr) | 61.2 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Ortech ODDIN-300 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Ortech ODDIN-300.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| [**Delta VDB200**](https://siematic-charleston.com/ventilation-fans/delta-vdb200/) | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| [**Broan FIN-180B**](https://siematic-charleston.com/ventilation-fans/broan-fin-180b/) | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |

## What percentage of room demand does Ortech ODDIN-300 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Ortech ODDIN-300 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Ortech ODDIN-300?

Match Ortech ODDIN-300 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 300 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around ENERGY STAR sones up to 300 sq ft
- **Optimal use:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Ortech ODDIN-300?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Ortech ODDIN-300.

### What bathroom square footage can Ortech ODDIN-300 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Ortech ODDIN-300 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Ortech ODDIN-300 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Ortech ODDIN-300.

### What happens to Ortech ODDIN-300 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Ortech ODDIN-300 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

### Where does Ortech ODDIN-300 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Ortech ODDIN-300 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Ortech ODDIN-300 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Ortech ODDIN-300 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Ortech ODDIN-300 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODDIN-300's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech ODDIN-300?

Ortech ODDIN-300 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech ODDIN-300's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODDIN-300's safe coverage footprint from 50 sq ft to 44 sq ft.

## What related resources expand on Ortech ODDIN-300?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [S&P PCD300IL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pcd300il/)
- [Ortech ODD-300-3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odd-300-3/)
- [Broan L300E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l300e/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)