title: "Ortech OIF4-140 Bath Fan (120 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/ortech-oif4-140/
description: "ENERGY STAR specs for Ortech OIF4-140: 120 CFM, 4.4 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Ortech OIF4-140 Exhaust Fan Specifications

ENERGY STAR PD #3999566 · In-line (single-port) · Qualified 2025-03-07

Verified Specification Summary

The Ortech OIF4-140 (Inline Fan 4inch) moves 120 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 4.4 CFM/W efficacy, sizing bathrooms up to 120 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OIF4-140 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 120 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 27.3 W (10.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech OIF4-140 vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech OIF4-140 (EPA filing PD #3999566) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Ortech registers 27 certified models, with SKU OIF4-140 (series: Inline Fan 4inch) (PD #3999566) certified since 2025-03-07. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.3 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 239.1 kWh/yr (~$38.26/yr) continuously. Closest competing matches include Greenheck SP-B110ES (118.0 CFM) and KORA SBF110N (119.2 CFM).

## How does duct geometry alter Ortech OIF4-140 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Ortech OIF4-140?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Ortech OIF4-140 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | OIF4-140 / Inline Fan 4inch | PD ID 3999566 (Qualified 2025-03-07) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (120 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Ortech OIF4-140 ventilate safely?

Sizing outputs below convert Ortech OIF4-140 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Ortech OIF4-140

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.0 kWh/yr (~$1.60/yr) | 27.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 239.1 kWh/yr (~$38.26/yr) | 27.3 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Ortech OIF4-140 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Greenheck SP-B110ES**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/) | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| [**KORA SBF110N**](https://siematic-charleston.com/ventilation-fans/kora-sbf110n/) | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |
| [**Broan 791LEDM**](https://siematic-charleston.com/ventilation-fans/broan-791ledm/) | 110 / 93.4 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Commercial Electric BPT14-24OD-H**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bpt14-24od-h/) | 110 / 98.1 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |

## Will Ortech OIF4-140 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Ortech OIF4-140 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Ortech OIF4-140 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Ortech OIF4-140.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 70 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 120 sq ft with 8-ft ceilings (106 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Ortech OIF4-140?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Ortech OIF4-140.

### How much airflow does Ortech OIF4-140 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Ortech OIF4-140 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Ortech OIF4-140 disturb adjacent bedrooms during night use?

Acoustic measurement places Ortech OIF4-140 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Ortech OIF4-140 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Ortech OIF4-140 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Ortech OIF4-140 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OIF4-140's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech OIF4-140?

Ortech OIF4-140 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech OIF4-140's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OIF4-140's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Ortech OIF4-140 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Ortech OIF4-140 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Ortech OIF4-140?

Do not force Ortech OIF4-140 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

## Which guides and calculators connect next to Ortech OIF4-140?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Ortech OIF4-140.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck CSP-A125 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-csp-a125/)
- [AERO PURE ABF110DHL5W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110dhl5w/)
- [Fantech FR 100 (411330) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fr-100-411330/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)