title: "Ortech OIF8-560 Bath Fan (380 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/ortech-oif8-560/
description: "ENERGY STAR specs for Ortech OIF8-560: 380 CFM, 4.2 CFM/W, 8 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Ortech OIF8-560 Exhaust Fan Specifications

ENERGY STAR PD #3999563 · In-line (single-port) · Qualified 2025-03-07

Verified Specification Summary

Homeowners specifying Ortech OIF8-560 gain 380 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it omits a published 0.1-inch sone rating and delivers 4.2 CFM/W efficacy, venting bathrooms up to 380 sq ft cleanly through 8 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OIF8-560 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 380 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.2 CFM/W (#774/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 90.5 W (33.0 kWh/yr)

- **Duct & Tier**: 8 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Ortech OIF8-560 vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech OIF8-560 (EPA filing PD #3999563) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 380 CFM (#10 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places OIF8-560 (series: Inline fan 8inch) (PD #3999563) among 27 Ortech entries qualified through 2025-03-07. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 90.5 watts, about 33.0 kWh/yr (~$5.28/yr at $0.16/kWh) for 1 hr/day shower timers or 792.8 kWh/yr (~$126.85/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

## Which exterior damper path suits Ortech OIF8-560 best?

Exterior roof or wall damper termination paired with insulated 8 in. diameter metal pipe prevents condensation buildup around Ortech OIF8-560 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Ortech OIF8-560 acoustic and static metrics stand?

Compare Ortech OIF8-560 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Ortech (27 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | OIF8-560 / Inline fan 8inch | PD ID 3999563 (Qualified 2025-03-07) |
| **Duct Connection** | 8 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (380 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Ortech OIF8-560 handle taller ceilings or walk-in tub steam?

Evaluate how Ortech OIF8-560 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Ortech OIF8-560

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 380 sq ft | 1 CFM/sq ft @ 380 CFM |
| Tall Bath (9-ft Ceiling) | Up to 337 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 330 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 33.0 kWh/yr (~$5.28/yr) | 90.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 792.8 kWh/yr (~$126.85/yr) | 90.5 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Ortech OIF8-560?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| [**Delta VDB200**](https://siematic-charleston.com/ventilation-fans/delta-vdb200/) | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| [**Broan FIN-180B**](https://siematic-charleston.com/ventilation-fans/broan-fin-180b/) | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |

## Is Ortech OIF8-560 sized right for your shower or tub room?

Check whether Ortech OIF8-560 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Ortech OIF8-560?

Match Ortech OIF8-560 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 330 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 380 CFM net static output
- **Optimal use:** Collar pairs with 8 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Ortech OIF8-560?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Ortech OIF8-560.

### What happens to Ortech OIF8-560 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Ortech OIF8-560 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 8 in. diameter collar.

### Where does Ortech OIF8-560 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Ortech OIF8-560 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Ortech OIF8-560 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Ortech OIF8-560 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Ortech OIF8-560 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OIF8-560's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Ortech OIF8-560?

Ortech OIF8-560 features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Ortech OIF8-560's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OIF8-560's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Ortech OIF8-560 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Ortech OIF8-560 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Ortech OIF8-560 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Ortech OIF8-560.

## How can you cross-check Ortech OIF8-560 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Ortech OIF8-560.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech FG 6M EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fg-6m-ec/)
- [Fantech FGC 6M EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-6m-ec/)
- [Fantech FGC 8 EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-8-ec/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)