title: "Panasonic Eco Solutions FV-0811RQC1 Bath Fan (110 CFM)"
url: https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-fv-0811rqc1/
description: "ENERGY STAR specs for Panasonic Eco Solutions FV-0811RQC1: 110 CFM, 4.9 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Panasonic Eco Solutions FV-0811RQC1 Exhaust Fan Specifications

ENERGY STAR PD #2390258 · Bathroom/Utility Room · Qualified 2022-01-07

Verified Specification Summary

Homeowners specifying Panasonic Eco Solutions FV-0811RQC1 gain 110 CFM at 0.1 in. w.g. (95.7 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, venting bathrooms up to 95 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic Eco Solutions FV-0811RQC1 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 95.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.9 CFM/W (#519/1,145)

- **Static Retention**: 87.0% @ 0.25"

- **Motor Draw**: 22.4 W (8.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic Eco Solutions FV-0811RQC1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic Eco Solutions FV-0811RQC1 (EPA filing PD #2390258) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.7 CFM out of 110 CFM (87.0% retention, 0.7 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Panasonic Eco Solutions's 9-unit lineup, FV-0811RQC1 (series: Whisper ChoiceAuto) carries PD #2390258 dating to 2022-01-07. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.4 watts, about 8.2 kWh/yr (~$1.31/yr at $0.16/kWh) for 1 hr/day shower timers or 196.2 kWh/yr (~$31.39/yr) continuously. Closest competing matches include Tech Drive TD-BF-10 (110.0 CFM) and Tech Drive TD-BF-10-H (110.0 CFM).

## Which exterior damper path suits Panasonic Eco Solutions FV-0811RQC1 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic Eco Solutions FV-0811RQC1 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Panasonic Eco Solutions FV-0811RQC1 acoustic and static metrics stand?

Compare Panasonic Eco Solutions FV-0811RQC1 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic Eco Solutions (9 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0811RQC1 / Whisper ChoiceAuto | PD ID 2390258 (Qualified 2022-01-07) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (95.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Panasonic Eco Solutions FV-0811RQC1 handle taller ceilings or walk-in tub steam?

Evaluate how Panasonic Eco Solutions FV-0811RQC1 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Panasonic Eco Solutions FV-0811RQC1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 85 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.2 kWh/yr (~$1.31/yr) | 22.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 196.2 kWh/yr (~$31.39/yr) | 22.4 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Panasonic Eco Solutions FV-0811RQC1?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Tech Drive TD-BF-10**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-10-H**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TG-H**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tg-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TGHS**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tghs/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**Tech Drive FA-BF-04-L(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-fa-bf-04-l-bl/) | 110 / 92.9 CFM | 1.5 sones | 4.5 CFM/W | 4 in. diameter |

## Is Panasonic Eco Solutions FV-0811RQC1 sized right for your shower or tub room?

Check whether Panasonic Eco Solutions FV-0811RQC1 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Panasonic Eco Solutions FV-0811RQC1?

Compare where Panasonic Eco Solutions FV-0811RQC1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 45 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 95.7 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Panasonic Eco Solutions FV-0811RQC1?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic Eco Solutions FV-0811RQC1.

### Is Panasonic Eco Solutions FV-0811RQC1 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Panasonic Eco Solutions FV-0811RQC1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Panasonic Eco Solutions FV-0811RQC1 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Panasonic Eco Solutions FV-0811RQC1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic Eco Solutions FV-0811RQC1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic Eco Solutions FV-0811RQC1?

Panasonic Eco Solutions FV-0811RQC1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic Eco Solutions FV-0811RQC1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic Eco Solutions FV-0811RQC1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Panasonic Eco Solutions FV-0811RQC1 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Panasonic Eco Solutions FV-0811RQC1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Panasonic Eco Solutions FV-0811RQC1 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic Eco Solutions FV-0811RQC1 lacks adequate reserve.

### How does Panasonic Eco Solutions FV-0811RQC1 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic Eco Solutions FV-0811RQC1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

## How can you cross-check Panasonic Eco Solutions FV-0811RQC1 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Panasonic Eco Solutions FV-0811RQC1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0511VF1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vf1/)
- [Panasonic FV-0511VFBL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfbl1/)
- [Panasonic Eco Solutions FV-0811RQ1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-fv-0811rq1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)