#  Panasonic Eco Solutions RG-V80A Exhaust Fan Specifications

ENERGY STAR PD #2669651 · Bathroom/Utility Room · Qualified 2023-07-21

Verified Specification Summary

Homeowners specifying Panasonic Eco Solutions RG-V80A gain 90 CFM at 0.1 in. w.g. (79.2 CFM at 0.25 in. w.g.) where it registers #412 of 607 in quietness (1.5 sones) and delivers 4.3 CFM/W efficacy, venting bathrooms up to 79 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic Eco Solutions RG-V80A Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 79.2 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 88.0% @ 0.25"

- **Motor Draw**: 20.9 W (7.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic Eco Solutions RG-V80A vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79.2 CFM out of 90 CFM (88.0% retention, 0.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2669651 verifies RG-V80A (series: Whisper Vanity) under Panasonic Eco Solutions (9 listed models, qualified 2023-07-21). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.9 watts, about 7.6 kWh/yr (~$1.22/yr at $0.16/kWh) for 1 hr/day shower timers or 183.1 kWh/yr (~$29.30/yr) continuously. Closest competing matches include Akicon AK1390N2-B (90.0 CFM) and Akicon AK1390N2-S (90.0 CFM).

## What acoustic percentile does Panasonic Eco Solutions RG-V80A occupy among 1,145 bath blowers?

Inspect how Panasonic Eco Solutions RG-V80A positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Panasonic Eco Solutions RG-V80A best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic Eco Solutions RG-V80A housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Panasonic Eco Solutions RG-V80A acoustic and static metrics stand?

Compare Panasonic Eco Solutions RG-V80A published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic Eco Solutions (9 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RG-V80A / Whisper Vanity | PD ID 2669651 (Qualified 2023-07-21) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (79.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Panasonic Eco Solutions RG-V80A handle taller ceilings or walk-in tub steam?

Evaluate how Panasonic Eco Solutions RG-V80A scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Panasonic Eco Solutions RG-V80A

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 79 sq ft | 1 CFM/sq ft @ 79.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 29 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.6 kWh/yr (~$1.22/yr) | 20.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 183.1 kWh/yr (~$29.30/yr) | 20.9 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Panasonic Eco Solutions RG-V80A?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Akicon AK1390N2-B**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-b/) | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-s/) | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-W**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-w/) | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N3-W/B/S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n3-w-b-s/) | 90 / 71.8 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| [**Ortech ODE-9010**](https://siematic-charleston.com/ventilation-fans/ortech-ode-9010/) | 90 / 81.3 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |

## Is Panasonic Eco Solutions RG-V80A sized right for your shower or tub room?

Check whether Panasonic Eco Solutions RG-V80A clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Panasonic Eco Solutions RG-V80A fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic Eco Solutions RG-V80A.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 29 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 79.2 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Panasonic Eco Solutions RG-V80A?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic Eco Solutions RG-V80A.

### Which bathroom layouts should pick a larger blower than Panasonic Eco Solutions RG-V80A?

Do not force Panasonic Eco Solutions RG-V80A into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Panasonic Eco Solutions RG-V80A retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Panasonic Eco Solutions RG-V80A produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Panasonic Eco Solutions RG-V80A disturb adjacent bedrooms during night use?

Acoustic measurement places Panasonic Eco Solutions RG-V80A at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Panasonic Eco Solutions RG-V80A continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Panasonic Eco Solutions RG-V80A draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Panasonic Eco Solutions RG-V80A pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic Eco Solutions RG-V80A's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic Eco Solutions RG-V80A?

Panasonic Eco Solutions RG-V80A features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic Eco Solutions RG-V80A's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic Eco Solutions RG-V80A's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Panasonic Eco Solutions RG-V80A code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic Eco Solutions RG-V80A clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## How can you cross-check Panasonic Eco Solutions RG-V80A against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Panasonic Eco Solutions RG-V80A.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Tech Drive TD-BF-11 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11/)
- [Utilitech 7105-09-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7105-09-l/)
- [Ortech ODE-9010 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-ode-9010/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)