Verified Specification Summary

The Panasonic FV-0511VFBL1 (WhisperFit DC with speaker) moves 110 CFM at 0.1 in. w.g. (111.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 10.2 CFM/W efficacy, sizing bathrooms up to 111 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VFBL1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 111.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.2 CFM/W (#179/1,145)

- **Static Retention**: 101.5% @ 0.25"

- **Motor Draw**: 10.8 W (3.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0511VFBL1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VFBL1 (EPA filing PD #4510685) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.7 CFM out of 110 CFM (101.5% retention, 13.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4510685 verifies FV-0511VFBL1 (series: WhisperFit DC with speaker) under Panasonic (92 listed models, qualified 2025-09-05). Lighting kit: Yes. At 10.2 CFM/W (#179 of 1,145, top 16.2% of 1,145 rated models, more efficient than 83.8% of rated models, 5.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How does duct geometry alter Panasonic FV-0511VFBL1 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Panasonic FV-0511VFBL1?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-0511VFBL1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0511VFBL1 / WhisperFit DC with speaker | PD ID 4510685 (Qualified 2025-09-05) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (111.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Panasonic FV-0511VFBL1 ventilate safely?

Sizing outputs below convert Panasonic FV-0511VFBL1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VFBL1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 111 sq ft | 1 CFM/sq ft @ 111.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 61 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 94.6 kWh/yr (~$15.14/yr) | 10.8 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Panasonic FV-0511VFBL1 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |

## Will Panasonic FV-0511VFBL1 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Panasonic FV-0511VFBL1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Panasonic FV-0511VFBL1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-0511VFBL1 for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 61 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 111 sq ft with 8-ft ceilings (99 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Panasonic FV-0511VFBL1?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-0511VFBL1.

### Does duct resistance cut Panasonic FV-0511VFBL1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-0511VFBL1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Panasonic FV-0511VFBL1 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-0511VFBL1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Panasonic FV-0511VFBL1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Panasonic FV-0511VFBL1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Panasonic FV-0511VFBL1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VFBL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0511VFBL1?

Panasonic FV-0511VFBL1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0511VFBL1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VFBL1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Panasonic FV-0511VFBL1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VFBL1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Panasonic FV-0511VFBL1 in a bathroom remodel?

Avoid specifying Panasonic FV-0511VFBL1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

## Which guides and calculators connect next to Panasonic FV-0511VFBL1?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Panasonic FV-0511VFBL1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0511VFBL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfbl1-4510686/)
- [Panasonic FV-0511VFC1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfc1-2381483/)
- [Panasonic FV-0511VF1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vf1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)