---
title: "Panasonic FV-0511VFC1 Bath Fan (110 (c1-2381483) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfc1-2381483/
description: "ENERGY STAR specs for Panasonic FV-0511VFC1: 110 CFM, 6.6 CFM/W, 3 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Panasonic FV-0511VFC1 Exhaust Fan Specifications

ENERGY STAR PD #2381483 · Bathroom/Utility Room · Qualified 2021-04-30

Verified Specification Summary

Rated for 110 CFM open-air (96.6 CFM at 0.25 in. w.g.), Panasonic FV-0511VFC1 omits a published 0.1-inch sone rating and delivers 6.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 96 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VFC1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 96.6 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 6.6 CFM/W (#433/1,145)

- **Static Retention**: 87.8% @ 0.25"

- **Motor Draw**: 16.7 W (6.1 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0511VFC1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VFC1 (EPA filing PD #2381483) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 96.6 CFM out of 110 CFM (87.8% retention, 0.1 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Panasonic FV-0511VFC1 (series: WhisperFit DC) under PD #2381483 (92 models registered, 2021-04-30). Lighting kit: No. At 6.6 CFM/W (#433 of 1,145, top 38.0% of 1,145 rated models, more efficient than 62.0% of rated models, 1.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7115-01 (100.0 CFM).

## How do flex elbows choke Panasonic FV-0511VFC1 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Panasonic FV-0511VFC1 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Panasonic FV-0511VFC1 meet residential exhaust fan code specs?

Inspect Panasonic FV-0511VFC1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0511VFC1 / WhisperFit DC | PD ID 2381483 (Qualified 2021-04-30) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (96.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Panasonic FV-0511VFC1 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Panasonic FV-0511VFC1 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VFC1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 96 sq ft | 1 CFM/sq ft @ 96.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 85 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 46 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |

## Which competing models share Panasonic FV-0511VFC1 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Utilitech 7115-01**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/) | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| [**Delta 100LED**](https://siematic-charleston.com/ventilation-fans/delta-100led/) | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| [**Delta GBR100LED**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led/) | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| [**Delta ITG100**](https://siematic-charleston.com/ventilation-fans/delta-itg100/) | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |

## How much airflow margin does Panasonic FV-0511VFC1 give your bath?

Run a quick local room-volume check for Panasonic FV-0511VFC1 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Panasonic FV-0511VFC1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-0511VFC1 for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 46 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 96 sq ft with 8-ft ceilings (85 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 3 in. diameter

## What should homeowners verify first about Panasonic FV-0511VFC1?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic FV-0511VFC1.

### Who should NOT install Panasonic FV-0511VFC1 in a bathroom remodel?

Avoid specifying Panasonic FV-0511VFC1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Panasonic FV-0511VFC1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-0511VFC1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Panasonic FV-0511VFC1 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-0511VFC1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Panasonic FV-0511VFC1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Panasonic FV-0511VFC1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Panasonic FV-0511VFC1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VFC1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0511VFC1?

Panasonic FV-0511VFC1 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0511VFC1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VFC1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Panasonic FV-0511VFC1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VFC1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

## Which GradeMark tools pair best with Panasonic FV-0511VFC1?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Panasonic FV-0511VFC1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0511VFL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfl1/)
- [Panasonic FV-0511VFL1K Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfl1k/)
- [Panasonic FV-0511VFBL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfbl1-4510686/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
