#  Panasonic FV-0511VFC1 Exhaust Fan Specifications

ENERGY STAR PD #2381482 · Bathroom/Utility Room · Qualified 2021-04-30

Verified Specification Summary

Homeowners specifying Panasonic FV-0511VFC1 gain 110 CFM at 0.1 in. w.g. (112.9 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 11.0 CFM/W efficacy, venting bathrooms up to 112 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VFC1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 112.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 11.0 CFM/W (#131/1,145)

- **Static Retention**: 102.6% @ 0.25"

- **Motor Draw**: 10.0 W (3.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0511VFC1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VFC1 (EPA filing PD #2381482) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.9 CFM out of 110 CFM (102.6% retention, 14.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU FV-0511VFC1 (series: WhisperFit DC) (PD #2381482) certified since 2021-04-30. Lighting kit: No. At 11.0 CFM/W (#131 of 1,145, top 12.0% of 1,145 rated models, more efficient than 88.0% of rated models, 6.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## Which exterior damper path suits Panasonic FV-0511VFC1 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic FV-0511VFC1 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Panasonic FV-0511VFC1 acoustic and static metrics stand?

Compare Panasonic FV-0511VFC1 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0511VFC1 / WhisperFit DC | PD ID 2381482 (Qualified 2021-04-30) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (112.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Panasonic FV-0511VFC1 handle taller ceilings or walk-in tub steam?

Evaluate how Panasonic FV-0511VFC1 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VFC1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.6 kWh/yr (~$0.58/yr) | 10.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 87.6 kWh/yr (~$14.02/yr) | 10.0 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Panasonic FV-0511VFC1?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |

## Is Panasonic FV-0511VFC1 sized right for your shower or tub room?

Check whether Panasonic FV-0511VFC1 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Panasonic FV-0511VFC1 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic FV-0511VFC1.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 62 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 112.9 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Panasonic FV-0511VFC1?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic FV-0511VFC1.

### Which bathroom layouts should pick a larger blower than Panasonic FV-0511VFC1?

Do not force Panasonic FV-0511VFC1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Panasonic FV-0511VFC1 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Panasonic FV-0511VFC1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Panasonic FV-0511VFC1 disturb adjacent bedrooms during night use?

Acoustic measurement places Panasonic FV-0511VFC1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Panasonic FV-0511VFC1 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Panasonic FV-0511VFC1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Panasonic FV-0511VFC1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VFC1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0511VFC1?

Panasonic FV-0511VFC1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0511VFC1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VFC1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Panasonic FV-0511VFC1 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VFC1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## How can you cross-check Panasonic FV-0511VFC1 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Panasonic FV-0511VFC1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0511VFL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfl1-2381977/)
- [Panasonic FV-0511VFL1K Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfl1k-2382169/)
- [Panasonic FV-0511VF1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vf1-2381481/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)