#  Panasonic FV-0511VFL1 Exhaust Fan Specifications

ENERGY STAR PD #2381976 · Bathroom/Utility Room · Qualified 2021-06-04

Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic FV-0511VFL1 delivers 110 CFM free-air (90.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 6.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 90 sq ft (8-ft height) or 80 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VFL1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 90.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 6.4 CFM/W (#438/1,145)

- **Static Retention**: 81.9% @ 0.25"

- **Motor Draw**: 17.2 W (6.3 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0511VFL1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VFL1 (EPA filing PD #2381976) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 90.1 CFM at 0.25 in. w.g. (81.9% retention, 5.8 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2381976 verifies FV-0511VFL1 (series: WhisperFit DC) under Panasonic (92 listed models, qualified 2021-06-04). Lighting kit: Yes. At 6.4 CFM/W (#438 of 1,145, top 38.8% of 1,145 rated models, more efficient than 61.2% of rated models, 1.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7115-01 (100.0 CFM).

## Why does rigid 3 in. diameter ducting protect Panasonic FV-0511VFL1 airflow?

Connecting Panasonic FV-0511VFL1 through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Panasonic FV-0511VFL1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV-0511VFL1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0511VFL1 / WhisperFit DC | PD ID 2381976 (Qualified 2021-06-04) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (90.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Panasonic FV-0511VFL1?

Calculated coverage metrics translate Panasonic FV-0511VFL1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VFL1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 90 sq ft | 1 CFM/sq ft @ 90.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 40 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.3 kWh/yr (~$1.01/yr) | 17.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 150.7 kWh/yr (~$24.11/yr) | 17.2 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Panasonic FV-0511VFL1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Utilitech 7115-01**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/) | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-10**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-10-H**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TG-H**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tg-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |

## Does Panasonic FV-0511VFL1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV-0511VFL1 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Panasonic FV-0511VFL1 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic FV-0511VFL1.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 40 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 90.1 CFM net static output
- **Target scenario:** Collar pairs with 3 in. diameter duct straight outdoors

## Which homeowner questions come up most for Panasonic FV-0511VFL1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV-0511VFL1.

### How much airflow does Panasonic FV-0511VFL1 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Panasonic FV-0511VFL1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.

### Will Panasonic FV-0511VFL1 disturb adjacent bedrooms during night use?

Acoustic measurement places Panasonic FV-0511VFL1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Panasonic FV-0511VFL1 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Panasonic FV-0511VFL1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Panasonic FV-0511VFL1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VFL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0511VFL1?

Panasonic FV-0511VFL1 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0511VFL1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VFL1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Panasonic FV-0511VFL1 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VFL1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Panasonic FV-0511VFL1?

Do not force Panasonic FV-0511VFL1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

## Where can you explore more benchmarks around Panasonic FV-0511VFL1?

Use the related reference pages and estimators below to cross-check Panasonic FV-0511VFL1 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0511VFL1K Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfl1k/)
- [Panasonic FV-0511VKSL3K Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3k-4682918/)
- [Panasonic FV-0511VFC1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vfc1-2381483/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)