title: "Panasonic FV-0511VKL3 Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vkl3/
description: "ENERGY STAR specs for Panasonic FV-0511VKL3: 110 CFM, 10.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Panasonic FV-0511VKL3 Exhaust Fan Specifications

ENERGY STAR PD #3442062 · Bathroom/Utility Room · Qualified 2024-03-15

Verified Specification Summary

Tested under HVI protocols, the Panasonic FV-0511VKL3 exhaust unit achieves 110 CFM at 0.1 in. w.g. (114.3 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 10.8 CFM/W efficacy, covering standard baths up to 114 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKL3 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 114.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.8 CFM/W (#140/1,145)

- **Static Retention**: 103.9% @ 0.25"

- **Motor Draw**: 10.2 W (3.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0511VKL3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VKL3 (EPA filing PD #3442062) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.3 CFM out of 110 CFM (103.9% retention, 16.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Panasonic maintains 92 active ENERGY STAR blowers; FV-0511VKL3 (series: Whisper Green Select) (PD #3442062) gained qualification on 2024-03-15. Lighting kit: Yes. At 10.8 CFM/W (#140 of 1,145, top 12.5% of 1,145 rated models, more efficient than 87.5% of rated models, 6.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.2 watts, about 3.7 kWh/yr (~$0.59/yr at $0.16/kWh) for 1 hr/day shower timers or 89.4 kWh/yr (~$14.30/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## What attic duct routing preserves Panasonic FV-0511VKL3 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic FV-0511VKL3, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Panasonic FV-0511VKL3 measure up on airflow and noise ratings?

Each row below breaks down Panasonic FV-0511VKL3 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0511VKL3 / Whisper Green Select | PD ID 3442062 (Qualified 2024-03-15) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (114.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Panasonic FV-0511VKL3 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VKL3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.7 kWh/yr (~$0.59/yr) | 10.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 89.4 kWh/yr (~$14.30/yr) | 10.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Panasonic FV-0511VKL3?

Compare Panasonic FV-0511VKL3 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |

## Can you size Panasonic FV-0511VKL3 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic FV-0511VKL3 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Panasonic FV-0511VKL3 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic FV-0511VKL3 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 114.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around ENERGY STAR sones up to 114 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Panasonic FV-0511VKL3?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic FV-0511VKL3.

### How loud is Panasonic FV-0511VKL3 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Panasonic FV-0511VKL3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Panasonic FV-0511VKL3 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Panasonic FV-0511VKL3 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Panasonic FV-0511VKL3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0511VKL3?

Panasonic FV-0511VKL3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0511VKL3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKL3's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Panasonic FV-0511VKL3 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VKL3 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Panasonic FV-0511VKL3?

Rule out Panasonic FV-0511VKL3 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Panasonic FV-0511VKL3 capacity?

Because static drag at 0.25 in. w.g. lowers Panasonic FV-0511VKL3 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

## What neighboring pages and tools support Panasonic FV-0511VKL3?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Panasonic FV-0511VKL3.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0511VKL3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vkl3-3442063/)
- [Panasonic FV-0511VKS3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vks3/)
- [Panasonic FV-0511VK3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vk3-4682896/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)