#  Panasonic FV-0511VKS3 Exhaust Fan Specifications

ENERGY STAR PD #4682897 · Bathroom/Utility Room · Qualified 2026-08-05

Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic FV-0511VKS3 delivers 110 CFM free-air (112.9 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 16.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 112 sq ft (8-ft height) or 100 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKS3 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 112.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 16.7 CFM/W (#1/1,145)

- **Static Retention**: 102.6% @ 0.25"

- **Motor Draw**: 6.6 W (2.4 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0511VKS3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VKS3 (EPA filing PD #4682897) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.9 CFM out of 110 CFM (102.6% retention, 14.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places FV-0511VKS3 (series: Whisper Green Select) (PD #4682897) among 92 Panasonic entries qualified through 2026-08-05. Lighting kit: No. At 16.7 CFM/W (#1 of 1,145, top 0.3% of 1,145 rated models, more efficient than 99.7% of rated models, 12.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.6 watts, about 2.4 kWh/yr (~$0.38/yr at $0.16/kWh) for 1 hr/day shower timers or 57.8 kWh/yr (~$9.25/yr) continuously. Closest competing matches include Broan ZB110HL1 (110.0 CFM) and Broan ZB110L1 (110.0 CFM).

## Why does rigid 6 in. diameter ducting protect Panasonic FV-0511VKS3 airflow?

Connecting Panasonic FV-0511VKS3 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Panasonic FV-0511VKS3 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV-0511VKS3 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0511VKS3 / Whisper Green Select | PD ID 4682897 (Qualified 2026-08-05) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (112.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Panasonic FV-0511VKS3?

Calculated coverage metrics translate Panasonic FV-0511VKS3 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VKS3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.4 kWh/yr (~$0.38/yr) | 6.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 57.8 kWh/yr (~$9.25/yr) | 6.6 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Panasonic FV-0511VKS3?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan ZB110HL1**](https://siematic-charleston.com/ventilation-fans/broan-zb110hl1/) | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
| [**Broan ZB110L1**](https://siematic-charleston.com/ventilation-fans/broan-zb110l1/) | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
| [**Broan ZB110ML1**](https://siematic-charleston.com/ventilation-fans/broan-zb110ml1/) | 110 / 113.2 CFM | Unpublished | 16.2 CFM/W | 6 in. diameter |
| [**Delta SIG80-110**](https://siematic-charleston.com/ventilation-fans/delta-sig80-110/) | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |
| [**Delta SIG80-110D**](https://siematic-charleston.com/ventilation-fans/delta-sig80-110d/) | 110 / 110.9 CFM | Unpublished | 15.3 CFM/W | 6 in. diameter |

## Does Panasonic FV-0511VKS3 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV-0511VKS3 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Panasonic FV-0511VKS3 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-0511VKS3 for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 62 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 112.9 CFM net static output
- **Best application:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Panasonic FV-0511VKS3?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV-0511VKS3.

### How many kWh per year does Panasonic FV-0511VKS3 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Panasonic FV-0511VKS3 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Panasonic FV-0511VKS3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKS3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0511VKS3?

Panasonic FV-0511VKS3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0511VKS3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKS3's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Panasonic FV-0511VKS3 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VKS3 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Panasonic FV-0511VKS3 in a bathroom remodel?

Avoid specifying Panasonic FV-0511VKS3 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Panasonic FV-0511VKS3 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-0511VKS3 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Panasonic FV-0511VKS3 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-0511VKS3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## Where can you explore more benchmarks around Panasonic FV-0511VKS3?

Use the related reference pages and estimators below to cross-check Panasonic FV-0511VKS3 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0511VKS3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vks3-4682898/)
- [Panasonic FV-0511VKS3S Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vks3s/)
- [Panasonic FV-0511VKL3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vkl3-3442063/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)