---
title: "Panasonic FV-0511VKSL3 Bath Fan (110 (l3-3442046) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3-3442046/
description: "ENERGY STAR specs for Panasonic FV-0511VKSL3: 110 CFM, 10.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Panasonic FV-0511VKSL3 Exhaust Fan Specifications

ENERGY STAR PD #3442046 · Bathroom/Utility Room · Qualified 2024-03-15

Verified Specification Summary

Rated for 110 CFM open-air (114.3 CFM at 0.25 in. w.g.), Panasonic FV-0511VKSL3 omits a published 0.1-inch sone rating and delivers 10.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 114 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VKSL3 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 114.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.8 CFM/W (#140/1,145)

- **Static Retention**: 103.9% @ 0.25"

- **Motor Draw**: 10.2 W (3.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0511VKSL3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VKSL3 (EPA filing PD #3442046) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.3 CFM out of 110 CFM (103.9% retention, 16.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU FV-0511VKSL3 (series: Whisper Green Select) (PD #3442046) certified since 2024-03-15. Lighting kit: Yes. At 10.8 CFM/W (#140 of 1,145, top 12.5% of 1,145 rated models, more efficient than 87.5% of rated models, 6.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.2 watts, about 3.7 kWh/yr (~$0.59/yr at $0.16/kWh) for 1 hr/day shower timers or 89.4 kWh/yr (~$14.30/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How do flex elbows choke Panasonic FV-0511VKSL3 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Panasonic FV-0511VKSL3 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Panasonic FV-0511VKSL3 meet residential exhaust fan code specs?

Inspect Panasonic FV-0511VKSL3 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0511VKSL3 / Whisper Green Select | PD ID 3442046 (Qualified 2024-03-15) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (114.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Panasonic FV-0511VKSL3 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Panasonic FV-0511VKSL3 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VKSL3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.7 kWh/yr (~$0.59/yr) | 10.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 89.4 kWh/yr (~$14.30/yr) | 10.2 W x 8,760 hrs / 1,000 |

## Which competing models share Panasonic FV-0511VKSL3 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |

## How much airflow margin does Panasonic FV-0511VKSL3 give your bath?

Run a quick local room-volume check for Panasonic FV-0511VKSL3 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Panasonic FV-0511VKSL3 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic FV-0511VKSL3 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 64 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 114 sq ft with 8-ft ceilings (101 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Panasonic FV-0511VKSL3?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic FV-0511VKSL3.

### What duct and room conditions disqualify Panasonic FV-0511VKSL3?

Rule out Panasonic FV-0511VKSL3 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Panasonic FV-0511VKSL3 capacity?

Because static drag at 0.25 in. w.g. lowers Panasonic FV-0511VKSL3 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Panasonic FV-0511VKSL3 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Panasonic FV-0511VKSL3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Panasonic FV-0511VKSL3 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Panasonic FV-0511VKSL3 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Panasonic FV-0511VKSL3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VKSL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0511VKSL3?

Panasonic FV-0511VKSL3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0511VKSL3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VKSL3's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Panasonic FV-0511VKSL3 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VKSL3 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## Which GradeMark tools pair best with Panasonic FV-0511VKSL3?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Panasonic FV-0511VKSL3.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0511VKSL3K Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3k/)
- [Panasonic FV-0511VQ1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vq1/)
- [Panasonic FV-0511VKSL3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
