title: "Panasonic FV-0511VQL1 Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vql1/
description: "ENERGY STAR specs for Panasonic FV-0511VQL1: 110 CFM, 10.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Panasonic FV-0511VQL1 Exhaust Fan Specifications

ENERGY STAR PD #2378302 · Bathroom/Utility Room · Qualified 2021-05-21

Verified Specification Summary

Rated for 110 CFM open-air (112.9 CFM at 0.25 in. w.g.), Panasonic FV-0511VQL1 omits a published 0.1-inch sone rating and delivers 10.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 112 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0511VQL1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 112.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.3 CFM/W (#175/1,145)

- **Static Retention**: 102.6% @ 0.25"

- **Motor Draw**: 10.7 W (3.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0511VQL1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0511VQL1 (EPA filing PD #2378302) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.9 CFM out of 110 CFM (102.6% retention, 14.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Panasonic maintains 92 active ENERGY STAR blowers; FV-0511VQL1 (series: WhisperCeiling DC) (PD #2378302) gained qualification on 2021-05-21. Lighting kit: Yes. At 10.3 CFM/W (#175 of 1,145, top 15.5% of 1,145 rated models, more efficient than 84.5% of rated models, 5.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.7 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 93.7 kWh/yr (~$14.99/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How do flex elbows choke Panasonic FV-0511VQL1 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Panasonic FV-0511VQL1 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Panasonic FV-0511VQL1 meet residential exhaust fan code specs?

Inspect Panasonic FV-0511VQL1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0511VQL1 / WhisperCeiling DC | PD ID 2378302 (Qualified 2021-05-21) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (112.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Panasonic FV-0511VQL1 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Panasonic FV-0511VQL1 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0511VQL1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 93.7 kWh/yr (~$14.99/yr) | 10.7 W x 8,760 hrs / 1,000 |

## Which competing models share Panasonic FV-0511VQL1 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |

## How much airflow margin does Panasonic FV-0511VQL1 give your bath?

Run a quick local room-volume check for Panasonic FV-0511VQL1 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Panasonic FV-0511VQL1 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic FV-0511VQL1.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 62 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 112 sq ft with 8-ft ceilings (100 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Panasonic FV-0511VQL1?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic FV-0511VQL1.

### Does running Panasonic FV-0511VQL1 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Panasonic FV-0511VQL1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Panasonic FV-0511VQL1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0511VQL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0511VQL1?

Panasonic FV-0511VQL1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0511VQL1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0511VQL1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Panasonic FV-0511VQL1 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0511VQL1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Panasonic FV-0511VQL1?

Do not force Panasonic FV-0511VQL1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Panasonic FV-0511VQL1 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Panasonic FV-0511VQL1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Panasonic FV-0511VQL1 disturb adjacent bedrooms during night use?

Acoustic measurement places Panasonic FV-0511VQL1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## Which GradeMark tools pair best with Panasonic FV-0511VQL1?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Panasonic FV-0511VQL1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0811RF2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0811rf2/)
- [Panasonic FV-0811RF2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0811rf2-2405528/)
- [Panasonic FV-0511VQCL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vqcl1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)