Verified Specification Summary

The Panasonic FV-0811RF1 (whisper Remodel) moves 100 CFM at 0.1 in. w.g. (103.6 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 4.0 CFM/W efficacy, sizing bathrooms up to 103 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0811RF1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 103.6 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.0 CFM/W (#847/1,145)

- **Static Retention**: 103.6% @ 0.25"

- **Motor Draw**: 25.0 W (9.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0811RF1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0811RF1 (EPA filing PD #2390260) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 103.6 CFM out of 100 CFM (103.6% retention, 15.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Panasonic FV-0811RF1 (series: whisper Remodel) under PD #2390260 (92 models registered, 2022-01-07). Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Anzzi EF-AZ106MB (100.0 CFM) and Anzzi EF-AZ106WH (100.0 CFM).

## How does duct geometry alter Panasonic FV-0811RF1 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Panasonic FV-0811RF1?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-0811RF1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0811RF1 / whisper Remodel | PD ID 2390260 (Qualified 2022-01-07) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (103.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Panasonic FV-0811RF1 ventilate safely?

Sizing outputs below convert Panasonic FV-0811RF1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0811RF1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Panasonic FV-0811RF1 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Anzzi EF-AZ106MB**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az106mb/) | 100 / 92.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ106WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az106wh/) | 100 / 92.8 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| [**Fantech SMPL100 (484302)**](https://siematic-charleston.com/ventilation-fans/fantech-smpl100-484302/) | 100 / 91.2 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| [**Fantech SMPL100L (484303)**](https://siematic-charleston.com/ventilation-fans/fantech-smpl100l-484303/) | 100 / 91.2 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| [**Hunter 90064A**](https://siematic-charleston.com/ventilation-fans/hunter-90064a/) | 100 / 89.6 CFM | 1.5 sones | 3.9 CFM/W | 4 in. diameter |

## Will Panasonic FV-0811RF1 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Panasonic FV-0811RF1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Panasonic FV-0811RF1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Panasonic FV-0811RF1 for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 53 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 103 sq ft with 8-ft ceilings (92 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Panasonic FV-0811RF1?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-0811RF1.

### When is Panasonic FV-0811RF1 undersized or poorly matched for a bath renovation?

Skip Panasonic FV-0811RF1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Panasonic FV-0811RF1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Panasonic FV-0811RF1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Panasonic FV-0811RF1 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Panasonic FV-0811RF1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Panasonic FV-0811RF1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Panasonic FV-0811RF1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0811RF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0811RF1?

Panasonic FV-0811RF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0811RF1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0811RF1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Panasonic FV-0811RF1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0811RF1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## Which guides and calculators connect next to Panasonic FV-0811RF1?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Panasonic FV-0811RF1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV0510VSCL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv0510vscl1/)
- [Panasonic FV0810VSS1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv0810vss1/)
- [Panasonic FV-0811RF1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0811rf1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)