title: "Panasonic FV-0811RFC1 Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-0811rfc1/
description: "ENERGY STAR specs for Panasonic FV-0811RFC1: 110 CFM, 6.1 CFM/W, 3 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Panasonic FV-0811RFC1 Exhaust Fan Specifications

ENERGY STAR PD #2405529 · Bathroom/Utility Room · Qualified 2022-12-09

Verified Specification Summary

The Panasonic FV-0811RFC1 (Whisper Remodel Auto) moves 110 CFM at 0.1 in. w.g. (92.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 6.1 CFM/W efficacy, sizing bathrooms up to 92 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0811RFC1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 92.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 6.1 CFM/W (#448/1,145)

- **Static Retention**: 83.7% @ 0.25"

- **Motor Draw**: 18.0 W (6.6 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-0811RFC1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0811RFC1 (EPA filing PD #2405529) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.1 CFM at 0.25 in. w.g. (83.7% retention, 4.0 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Panasonic maintains 92 active ENERGY STAR blowers; FV-0811RFC1 (series: Whisper Remodel Auto) (PD #2405529) gained qualification on 2022-12-09. Lighting kit: No. At 6.1 CFM/W (#448 of 1,145, top 40.0% of 1,145 rated models, more efficient than 60.0% of rated models, 1.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.0 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 157.7 kWh/yr (~$25.23/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Tech Drive TD-BF-10 (110.0 CFM).

## How does duct geometry alter Panasonic FV-0811RFC1 static pressure?

Smooth 3 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Panasonic FV-0811RFC1?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-0811RFC1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-0811RFC1 / Whisper Remodel Auto | PD ID 2405529 (Qualified 2022-12-09) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (92.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Panasonic FV-0811RFC1 ventilate safely?

Sizing outputs below convert Panasonic FV-0811RFC1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0811RFC1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 157.7 kWh/yr (~$25.23/yr) | 18.0 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Panasonic FV-0811RFC1 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Tech Drive TD-BF-10**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-10-H**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TG-H**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tg-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TGHS**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tghs/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |

## Will Panasonic FV-0811RFC1 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Panasonic FV-0811RFC1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Panasonic FV-0811RFC1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-0811RFC1 for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 42 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 92 sq ft with 8-ft ceilings (81 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 3 in. diameter

## What key rules and numbers govern Panasonic FV-0811RFC1?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-0811RFC1.

### Does duct resistance cut Panasonic FV-0811RFC1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-0811RFC1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Panasonic FV-0811RFC1 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-0811RFC1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Panasonic FV-0811RFC1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Panasonic FV-0811RFC1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Panasonic FV-0811RFC1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0811RFC1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-0811RFC1?

Panasonic FV-0811RFC1 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-0811RFC1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0811RFC1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Panasonic FV-0811RFC1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0811RFC1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Panasonic FV-0811RFC1 in a bathroom remodel?

Avoid specifying Panasonic FV-0811RFC1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

## Which guides and calculators connect next to Panasonic FV-0811RFC1?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Panasonic FV-0811RFC1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-0811RFC1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0811rfc1-2405530/)
- [Panasonic FV-0811RFL2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0811rfl2/)
- [Panasonic FV-0811RF2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0811rf2-2405528/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)