title: "Panasonic FV-1115VK3 Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vk3/
description: "ENERGY STAR specs for Panasonic FV-1115VK3: 150 CFM, 13.7 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Panasonic FV-1115VK3 Exhaust Fan Specifications

ENERGY STAR PD #3543366 · Bathroom/Utility Room · Qualified 2024-06-07

Verified Specification Summary

Homeowners specifying Panasonic FV-1115VK3 gain 150 CFM at 0.1 in. w.g. (158.7 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 13.7 CFM/W efficacy, venting bathrooms up to 158 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-1115VK3 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 158.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 13.7 CFM/W (#46/1,145)

- **Static Retention**: 105.8% @ 0.25"

- **Motor Draw**: 10.9 W (4.0 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-1115VK3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-1115VK3 (EPA filing PD #3543366) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 158.7 CFM out of 150 CFM (105.8% retention, 18.1 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Panasonic's 92-unit lineup, FV-1115VK3 (series: Whisper Green Select) carries PD #3543366 dating to 2024-06-07. Lighting kit: No. At 13.7 CFM/W (#46 of 1,145, top 4.1% of 1,145 rated models, more efficient than 95.9% of rated models, 9.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.9 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 95.5 kWh/yr (~$15.28/yr) continuously. Closest competing matches include Broan-Nutone PTE1115RK (150.0 CFM) and Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF (150.0 CFM).

## Which exterior damper path suits Panasonic FV-1115VK3 best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Panasonic FV-1115VK3 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Panasonic FV-1115VK3 acoustic and static metrics stand?

Compare Panasonic FV-1115VK3 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-1115VK3 / Whisper Green Select | PD ID 3543366 (Qualified 2024-06-07) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (158.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Panasonic FV-1115VK3 handle taller ceilings or walk-in tub steam?

Evaluate how Panasonic FV-1115VK3 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Panasonic FV-1115VK3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 158 sq ft | 1 CFM/sq ft @ 158.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 141 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 108 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.0 kWh/yr (~$0.64/yr) | 10.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 95.5 kWh/yr (~$15.28/yr) | 10.9 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Panasonic FV-1115VK3?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan-Nutone PTE1115RK**](https://siematic-charleston.com/ventilation-fans/broan-nutone-pte1115rk/) | 150 / 154.4 CFM | Unpublished | 14.2 CFM/W | 6 in. diameter |
| [**Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF**](https://siematic-charleston.com/ventilation-fans/broan-nutone-pte1115rk-pte1115h-with-pte1115rkf/) | 150 / 154.4 CFM | Unpublished | 14.2 CFM/W | 6 in. diameter |
| [**Broan-Nutone PTEL1115RK**](https://siematic-charleston.com/ventilation-fans/broan-nutone-ptel1115rk/) | 150 / 154.4 CFM | Unpublished | 14.2 CFM/W | 6 in. diameter |
| [**Broan PTE1115RKY**](https://siematic-charleston.com/ventilation-fans/broan-pte1115rky/) | 150 / 154.4 CFM | Unpublished | 14.2 CFM/W | 6 in. diameter |
| [**Fantech S110-130-150 (484315)**](https://siematic-charleston.com/ventilation-fans/fantech-s110-130-150-484315/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |

## Is Panasonic FV-1115VK3 sized right for your shower or tub room?

Check whether Panasonic FV-1115VK3 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Panasonic FV-1115VK3?

Compare where Panasonic FV-1115VK3 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 108 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 158.7 CFM net static output
- **Suited to:** Collar pairs with 6 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Panasonic FV-1115VK3?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic FV-1115VK3.

### Can Panasonic FV-1115VK3 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Panasonic FV-1115VK3 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Panasonic FV-1115VK3 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic FV-1115VK3 lacks adequate reserve.

### How does Panasonic FV-1115VK3 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic FV-1115VK3 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Panasonic FV-1115VK3 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Panasonic FV-1115VK3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Panasonic FV-1115VK3 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Panasonic FV-1115VK3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-1115VK3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-1115VK3?

Panasonic FV-1115VK3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-1115VK3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-1115VK3's safe coverage footprint from 50 sq ft to 44 sq ft.

## How can you cross-check Panasonic FV-1115VK3 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Panasonic FV-1115VK3.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-1115VK3 with FV-VS15VK1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vk3-with-fv-vs15vk1/)
- [Panasonic FV-1115VKL3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vkl3/)
- [Panasonic Eco Solutions FV-1315RQ1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-fv-1315rq1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)