---
title: "Panasonic FV-1115VKL3 with FV-VS15VK1 Bath Fan (150 CFM)"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vkl3-with-fv-vs15vk1/
description: "ENERGY STAR specs for Panasonic FV-1115VKL3 with FV-VS15VK1: 150 CFM, 12.2 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Panasonic FV-1115VKL3 with FV-VS15VK1 Exhaust Fan Specifications

ENERGY STAR PD #3477592 · Bathroom/Utility Room · Qualified 2024-05-03

Verified Specification Summary

The Panasonic FV-1115VKL3 with FV-VS15VK1 (Whisper Green Select) moves 150 CFM at 0.1 in. w.g. (152.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 12.2 CFM/W efficacy, sizing bathrooms up to 152 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-1115VKL3 with FV-VS15VK1 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 152.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 12.2 CFM/W (#76/1,145)

- **Static Retention**: 101.4% @ 0.25"

- **Motor Draw**: 12.3 W (4.5 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-1115VKL3 with FV-VS15VK1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-1115VKL3 with FV-VS15VK1 (EPA filing PD #3477592) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 152.1 CFM out of 150 CFM (101.4% retention, 13.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Panasonic's 92-unit lineup, FV-1115VKL3 with FV-VS15VK1 (series: Whisper Green Select) carries PD #3477592 dating to 2024-05-03. Lighting kit: Yes. At 12.2 CFM/W (#76 of 1,145, top 6.7% of 1,145 rated models, more efficient than 93.3% of rated models, 7.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.3 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 107.7 kWh/yr (~$17.23/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Fantech S110-130-150 (484315) (150.0 CFM).

## How does duct geometry alter Panasonic FV-1115VKL3 with FV-VS15VK1 static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Panasonic FV-1115VKL3 with FV-VS15VK1?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-1115VKL3 with FV-VS15VK1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-1115VKL3 with FV-VS15VK1 / Whisper Green Select | PD ID 3477592 (Qualified 2024-05-03) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (152.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Panasonic FV-1115VKL3 with FV-VS15VK1 ventilate safely?

Sizing outputs below convert Panasonic FV-1115VKL3 with FV-VS15VK1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Panasonic FV-1115VKL3 with FV-VS15VK1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 152 sq ft | 1 CFM/sq ft @ 152.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 135 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 102 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 107.7 kWh/yr (~$17.23/yr) | 12.3 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Panasonic FV-1115VKL3 with FV-VS15VK1 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**Fantech S110-130-150 (484315)**](https://siematic-charleston.com/ventilation-fans/fantech-s110-130-150-484315/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| [**Fantech S110-130-150L (484316)**](https://siematic-charleston.com/ventilation-fans/fantech-s110-130-150l-484316/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| [**Fantech SC110-130-150H (484317)**](https://siematic-charleston.com/ventilation-fans/fantech-sc110-130-150h-484317/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| [**Fantech SC110-130-150LH (484318)**](https://siematic-charleston.com/ventilation-fans/fantech-sc110-130-150lh-484318/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |

## Will Panasonic FV-1115VKL3 with FV-VS15VK1 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Panasonic FV-1115VKL3 with FV-VS15VK1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Panasonic FV-1115VKL3 with FV-VS15VK1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-1115VKL3 with FV-VS15VK1 for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 102 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 152 sq ft with 8-ft ceilings (135 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What key rules and numbers govern Panasonic FV-1115VKL3 with FV-VS15VK1?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-1115VKL3 with FV-VS15VK1.

### Does duct resistance cut Panasonic FV-1115VKL3 with FV-VS15VK1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-1115VKL3 with FV-VS15VK1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Panasonic FV-1115VKL3 with FV-VS15VK1 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-1115VKL3 with FV-VS15VK1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Panasonic FV-1115VKL3 with FV-VS15VK1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Panasonic FV-1115VKL3 with FV-VS15VK1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Panasonic FV-1115VKL3 with FV-VS15VK1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-1115VKL3 with FV-VS15VK1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-1115VKL3 with FV-VS15VK1?

Panasonic FV-1115VKL3 with FV-VS15VK1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-1115VKL3 with FV-VS15VK1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-1115VKL3 with FV-VS15VK1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Panasonic FV-1115VKL3 with FV-VS15VK1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-1115VKL3 with FV-VS15VK1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Panasonic FV-1115VKL3 with FV-VS15VK1 in a bathroom remodel?

Avoid specifying Panasonic FV-1115VKL3 with FV-VS15VK1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

## Which guides and calculators connect next to Panasonic FV-1115VKL3 with FV-VS15VK1?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Panasonic FV-1115VKL3 with FV-VS15VK1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-1115VQ1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vq1/)
- [Panasonic FV-1115VQL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vql1/)
- [Panasonic FV-1115VKL3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vkl3/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
