#  Panasonic FV-1115VQ1 Exhaust Fan Specifications

ENERGY STAR PD #2337780 · Bathroom/Utility Room · Qualified 2019-05-03

Verified Specification Summary

Tested under HVI protocols, the Panasonic FV-1115VQ1 exhaust unit achieves 150 CFM at 0.1 in. w.g. (154.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 12.9 CFM/W efficacy, covering standard baths up to 154 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-1115VQ1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 154.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 12.9 CFM/W (#54/1,145)

- **Static Retention**: 103.1% @ 0.25"

- **Motor Draw**: 11.6 W (4.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-1115VQ1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-1115VQ1 (EPA filing PD #2337780) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 154.7 CFM out of 150 CFM (103.1% retention, 15.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2337780 verifies FV-1115VQ1 (series: WhisperCeiling DC) under Panasonic (92 listed models, qualified 2019-05-03). Lighting kit: No. At 12.9 CFM/W (#54 of 1,145, top 5.2% of 1,145 rated models, more efficient than 94.8% of rated models, 8.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Fantech S110-130-150 (484315) (150.0 CFM).

## What attic duct routing preserves Panasonic FV-1115VQ1 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic FV-1115VQ1, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Panasonic FV-1115VQ1 measure up on airflow and noise ratings?

Each row below breaks down Panasonic FV-1115VQ1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-1115VQ1 / WhisperCeiling DC | PD ID 2337780 (Qualified 2019-05-03) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (154.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Panasonic FV-1115VQ1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic FV-1115VQ1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 154 sq ft | 1 CFM/sq ft @ 154.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 137 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 104 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 101.6 kWh/yr (~$16.26/yr) | 11.6 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Panasonic FV-1115VQ1?

Compare Panasonic FV-1115VQ1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**Fantech S110-130-150 (484315)**](https://siematic-charleston.com/ventilation-fans/fantech-s110-130-150-484315/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| [**Fantech S110-130-150L (484316)**](https://siematic-charleston.com/ventilation-fans/fantech-s110-130-150l-484316/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| [**Fantech SC110-130-150H (484317)**](https://siematic-charleston.com/ventilation-fans/fantech-sc110-130-150h-484317/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| [**Fantech SC110-130-150LH (484318)**](https://siematic-charleston.com/ventilation-fans/fantech-sc110-130-150lh-484318/) | 150 / 150 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |

## Can you size Panasonic FV-1115VQ1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic FV-1115VQ1 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Panasonic FV-1115VQ1?

Match Panasonic FV-1115VQ1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 154.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around ENERGY STAR sones up to 154 sq ft
- **Optimal use:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Panasonic FV-1115VQ1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic FV-1115VQ1.

### What bathroom square footage can Panasonic FV-1115VQ1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-1115VQ1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Panasonic FV-1115VQ1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic FV-1115VQ1.

### What happens to Panasonic FV-1115VQ1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic FV-1115VQ1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

### Where does Panasonic FV-1115VQ1 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Panasonic FV-1115VQ1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Panasonic FV-1115VQ1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic FV-1115VQ1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Panasonic FV-1115VQ1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-1115VQ1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-1115VQ1?

Panasonic FV-1115VQ1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-1115VQ1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-1115VQ1's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Panasonic FV-1115VQ1?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Panasonic FV-1115VQ1.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-1115VQL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vql1/)
- [Panasonic FV-1315RQ2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1315rq2/)
- [Panasonic FV-1115VKL3 with FV-VS15VK1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vkl3-with-fv-vs15vk1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)