title: "Panasonic FV-1315RQ2 Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-1315rq2/
description: "ENERGY STAR specs for Panasonic FV-1315RQ2: 150 CFM, 10.6 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Panasonic FV-1315RQ2 Exhaust Fan Specifications

ENERGY STAR PD #2405524 · Bathroom/Utility Room · Qualified 2022-06-24

Verified Specification Summary

In EPA dataset 8dv7-nngq, Panasonic FV-1315RQ2 tests at 150 CFM free discharge (143.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 143 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-1315RQ2 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 143.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.6 CFM/W (#152/1,145)

- **Static Retention**: 95.5% @ 0.25"

- **Motor Draw**: 14.2 W (5.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-1315RQ2 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-1315RQ2 (EPA filing PD #2405524) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 143.3 CFM out of 150 CFM (95.5% retention, 7.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU FV-1315RQ2 (series: Whisper Choice) (PD #2405524) certified since 2022-06-24. Lighting kit: No. At 10.6 CFM/W (#152 of 1,145, top 13.7% of 1,145 rated models, more efficient than 86.3% of rated models, 5.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.2 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 124.4 kWh/yr (~$19.90/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).

## Why avoid unvented attic termination with Panasonic FV-1315RQ2?

Under ASHRAE 62.2 best practice, Panasonic FV-1315RQ2 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Panasonic FV-1315RQ2?

Before cutting ceiling drywall or sizing attic transitions for Panasonic FV-1315RQ2, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-1315RQ2 / Whisper Choice | PD ID 2405524 (Qualified 2022-06-24) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (143.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Panasonic FV-1315RQ2?

Bathroom ventilation sizing below maps Panasonic FV-1315RQ2 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Panasonic FV-1315RQ2

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 143 sq ft | 1 CFM/sq ft @ 143.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 127 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 93 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 124.4 kWh/yr (~$19.90/yr) | 14.2 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Panasonic FV-1315RQ2 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Panasonic FV-1315RQ2.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**KORA SBF160DC-MS**](https://siematic-charleston.com/ventilation-fans/kora-sbf160dc-ms/) | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**Loren Cook Company GCVF 300**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-300/) | 167 / N/A CFM | 1.9 sones | 9.9 CFM/W | 8 x 6 in. rectangular |
| [**S&P PCD150**](https://siematic-charleston.com/ventilation-fans/s-p-pcd150/) | 150 / 159.6 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| [**Broan QTXE110150DC**](https://siematic-charleston.com/ventilation-fans/broan-qtxe110150dc/) | 150 / 147.8 CFM | Unpublished | 11.0 CFM/W | 6 in. diameter |

## What percentage of room demand does Panasonic FV-1315RQ2 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Panasonic FV-1315RQ2 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Panasonic FV-1315RQ2?

Compare where Panasonic FV-1315RQ2 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 143.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around ENERGY STAR sones up to 143 sq ft
- **Suited to:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Panasonic FV-1315RQ2?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Panasonic FV-1315RQ2.

### How does Panasonic FV-1315RQ2 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic FV-1315RQ2 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Panasonic FV-1315RQ2 quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Panasonic FV-1315RQ2 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Panasonic FV-1315RQ2 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Panasonic FV-1315RQ2 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-1315RQ2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-1315RQ2?

Panasonic FV-1315RQ2 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-1315RQ2's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-1315RQ2's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Panasonic FV-1315RQ2 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Panasonic FV-1315RQ2 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Panasonic FV-1315RQ2 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic FV-1315RQ2 lacks adequate reserve.

## What related resources expand on Panasonic FV-1315RQ2?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic RG-C1315A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-c1315a/)
- [Panasonic RG-C1315LA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-c1315la/)
- [Panasonic FV-1115VQL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vql1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)