title: "Panasonic FV-13NLFS1 Bath Fan (130 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-13nlfs1/
description: "ENERGY STAR specs for Panasonic FV-13NLFS1: 130 CFM, 7.5 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Panasonic FV-13NLFS1 Exhaust Fan Specifications

ENERGY STAR PD #4687954 · In-line (single-port) · Qualified 2026-07-08

Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic FV-13NLFS1 delivers 130 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 7.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 130 sq ft (8-ft height) or 115 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-13NLFS1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 7.5 CFM/W (#390/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 17.3 W (6.3 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-13NLFS1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-13NLFS1 (EPA filing PD #4687954) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Panasonic FV-13NLFS1 (series: WhisperFresh) under PD #4687954 (92 models registered, 2026-07-08). Lighting kit: No. At 7.5 CFM/W (#390 of 1,145, top 34.1% of 1,145 rated models, more efficient than 65.9% of rated models, 2.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.3 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 151.5 kWh/yr (~$24.24/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

## Why does rigid 6 in. diameter ducting protect Panasonic FV-13NLFS1 airflow?

Connecting Panasonic FV-13NLFS1 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Panasonic FV-13NLFS1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV-13NLFS1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-13NLFS1 / WhisperFresh | PD ID 4687954 (Qualified 2026-07-08) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (130 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Panasonic FV-13NLFS1?

Calculated coverage metrics translate Panasonic FV-13NLFS1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic FV-13NLFS1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 130 sq ft | 1 CFM/sq ft @ 130 CFM |
| Tall Bath (9-ft Ceiling) | Up to 115 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 80 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.3 kWh/yr (~$1.01/yr) | 17.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 151.5 kWh/yr (~$24.24/yr) | 17.3 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Panasonic FV-13NLFS1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |

## Does Panasonic FV-13NLFS1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV-13NLFS1 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Panasonic FV-13NLFS1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Panasonic FV-13NLFS1 for residential use.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 80 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 130 CFM net static output
- **Primary match:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Panasonic FV-13NLFS1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV-13NLFS1.

### What electrical efficiency and runtime kWh define Panasonic FV-13NLFS1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Panasonic FV-13NLFS1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-13NLFS1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-13NLFS1?

Panasonic FV-13NLFS1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-13NLFS1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-13NLFS1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Panasonic FV-13NLFS1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-13NLFS1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Panasonic FV-13NLFS1 undersized or poorly matched for a bath renovation?

Skip Panasonic FV-13NLFS1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Panasonic FV-13NLFS1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Panasonic FV-13NLFS1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Panasonic FV-13NLFS1 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Panasonic FV-13NLFS1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

## Where can you explore more benchmarks around Panasonic FV-13NLFS1?

Use the related reference pages and estimators below to cross-check Panasonic FV-13NLFS1 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV-13NLFSC1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-13nlfsc1/)
- [Revent RVL110120130 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvl110120130/)
- [Fantech Rn1-C (606281) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-rn1-c-606281/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)