title: "Panasonic FV-30VQ3 Bath Fan (280 CFM, 2.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv-30vq3/
description: "ENERGY STAR specs for Panasonic FV-30VQ3: 280 CFM, 2.0 sones (#522 of 607), 4.4 CFM/W, 6 in. diameter and 5 closest peer fans."
---

#  Panasonic FV-30VQ3 Exhaust Fan Specifications

ENERGY STAR PD #3892183 · Bathroom/Utility Room · Qualified 2024-12-20

Verified Specification Summary

The Panasonic FV-30VQ3 (WhisperCeiling) moves 280 CFM at 0.1 in. w.g. (254.4 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 4.4 CFM/W efficacy, sizing bathrooms up to 254 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-30VQ3 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 280 / 254.4 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 90.9% @ 0.25"

- **Motor Draw**: 63.6 W (23.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV-30VQ3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 254.4 CFM out of 280 CFM (90.9% retention, 3.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU FV-30VQ3 (series: WhisperCeiling) (PD #3892183) certified since 2024-12-20. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 63.6 watts, about 23.2 kWh/yr (~$3.71/yr at $0.16/kWh) for 1 hr/day shower timers or 557.1 kWh/yr (~$89.14/yr) continuously. Closest competing matches include Fantech FR 150 (411334) (280.0 CFM) and S&P TD-150S (270.0 CFM).

## Where does Panasonic FV-30VQ3 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.

## How does duct geometry alter Panasonic FV-30VQ3 static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Panasonic FV-30VQ3?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-30VQ3 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV-30VQ3 / WhisperCeiling | PD ID 3892183 (Qualified 2024-12-20) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (254.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Panasonic FV-30VQ3 ventilate safely?

Sizing outputs below convert Panasonic FV-30VQ3 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Panasonic FV-30VQ3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 254 sq ft | 1 CFM/sq ft @ 254.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 226 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 204 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 23.2 kWh/yr (~$3.71/yr) | 63.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 557.1 kWh/yr (~$89.14/yr) | 63.6 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Panasonic FV-30VQ3 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Fantech FR 150 (411334)**](https://siematic-charleston.com/ventilation-fans/fantech-fr-150-411334/) | 280 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |
| [**S&P TD-150S**](https://siematic-charleston.com/ventilation-fans/s-p-td-150s/) | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| [**Broan L250E**](https://siematic-charleston.com/ventilation-fans/broan-l250e/) | 270 / 245 CFM | Unpublished | 4.6 CFM/W | 8 in. diameter |
| [**Broan L300EL**](https://siematic-charleston.com/ventilation-fans/broan-l300el/) | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| [**Dayton 3DPE6A**](https://siematic-charleston.com/ventilation-fans/dayton-3dpe6a/) | 270 / N/A CFM | 2.2 sones (+0.20) | 4.3 CFM/W | 8 x 8 in. rectangular |

## Will Panasonic FV-30VQ3 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Panasonic FV-30VQ3 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Panasonic FV-30VQ3?

Match Panasonic FV-30VQ3 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 204 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 254 sq ft with 8-ft ceilings (226 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What key rules and numbers govern Panasonic FV-30VQ3?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-30VQ3.

### What bathroom square footage can Panasonic FV-30VQ3 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-30VQ3 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Panasonic FV-30VQ3 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic FV-30VQ3.

### What happens to Panasonic FV-30VQ3 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic FV-30VQ3 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

### Where does Panasonic FV-30VQ3 sit on acoustic comfort for senior homeowners?

Measuring 2.0 sones, Panasonic FV-30VQ3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Panasonic FV-30VQ3 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic FV-30VQ3 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Panasonic FV-30VQ3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-30VQ3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV-30VQ3?

Panasonic FV-30VQ3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV-30VQ3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-30VQ3's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which guides and calculators connect next to Panasonic FV-30VQ3?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Panasonic FV-30VQ3.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Zephyr AK8400BS-ES Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/zephyr-ak8400bs-es/)
- [Broan AMG03RSS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-amg03rss/)
- [Delta Pro300 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-pro300/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)