title: "Panasonic FV0810VSS1 Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-fv0810vss1/
description: "ENERGY STAR specs for Panasonic FV0810VSS1: 100 CFM, 8.2 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Panasonic FV0810VSS1 Exhaust Fan Specifications

ENERGY STAR PD #2369821 · Bathroom/Utility Room · Qualified 2020-11-20

Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic FV0810VSS1 delivers 100 CFM free-air (102.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 102 sq ft (8-ft height) or 91 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV0810VSS1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 102.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 8.2 CFM/W (#330/1,145)

- **Static Retention**: 102.5% @ 0.25"

- **Motor Draw**: 12.2 W (4.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic FV0810VSS1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV0810VSS1 (EPA filing PD #2369821) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 102.5 CFM out of 100 CFM (102.5% retention, 14.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Panasonic FV0810VSS1 (series: Whisper Value) under PD #2369821 (92 models registered, 2020-11-20). Lighting kit: No. At 8.2 CFM/W (#330 of 1,145, top 29.4% of 1,145 rated models, more efficient than 70.6% of rated models, 3.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta ITG100ELED (100.0 CFM).

## Why does rigid 4 in. diameter ducting protect Panasonic FV0810VSS1 airflow?

Connecting Panasonic FV0810VSS1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Panasonic FV0810VSS1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV0810VSS1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FV0810VSS1 / Whisper Value | PD ID 2369821 (Qualified 2020-11-20) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (102.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Panasonic FV0810VSS1?

Calculated coverage metrics translate Panasonic FV0810VSS1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic FV0810VSS1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 102 sq ft | 1 CFM/sq ft @ 102.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 91 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 52 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.9 kWh/yr (~$17.10/yr) | 12.2 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Panasonic FV0810VSS1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Does Panasonic FV0810VSS1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV0810VSS1 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Panasonic FV0810VSS1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Panasonic FV0810VSS1 for residential use.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 52 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 102.5 CFM net static output
- **Primary match:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Panasonic FV0810VSS1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV0810VSS1.

### What electrical efficiency and runtime kWh define Panasonic FV0810VSS1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Panasonic FV0810VSS1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV0810VSS1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic FV0810VSS1?

Panasonic FV0810VSS1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic FV0810VSS1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV0810VSS1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Panasonic FV0810VSS1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Panasonic FV0810VSS1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Panasonic FV0810VSS1 undersized or poorly matched for a bath renovation?

Skip Panasonic FV0810VSS1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Panasonic FV0810VSS1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Panasonic FV0810VSS1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Panasonic FV0810VSS1 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Panasonic FV0810VSS1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

## Where can you explore more benchmarks around Panasonic FV0810VSS1?

Use the related reference pages and estimators below to cross-check Panasonic FV0810VSS1 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic FV0810VSSL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv0810vssl1/)
- [Panasonic RG-T810A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-t810a/)
- [Panasonic FV0510VSCL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv0510vscl1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)