title: "Panasonic RG-C1315LA Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/panasonic-rg-c1315la/
description: "ENERGY STAR specs for Panasonic RG-C1315LA: 150 CFM, 10.6 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Panasonic RG-C1315LA Exhaust Fan Specifications

ENERGY STAR PD #2405791 · Bathroom/Utility Room · Qualified 2022-02-18

Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic RG-C1315LA delivers 150 CFM free-air (143.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 143 sq ft (8-ft height) or 127 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-C1315LA Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 143.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.6 CFM/W (#152/1,145)

- **Static Retention**: 95.5% @ 0.25"

- **Motor Draw**: 14.2 W (5.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic RG-C1315LA vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic RG-C1315LA (EPA filing PD #2405791) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 143.3 CFM out of 150 CFM (95.5% retention, 7.8 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU RG-C1315LA (series: Whisper Choice) (PD #2405791) certified since 2022-02-18. Lighting kit: Yes. At 10.6 CFM/W (#152 of 1,145, top 13.7% of 1,145 rated models, more efficient than 86.3% of rated models, 5.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.2 watts, about 5.2 kWh/yr (~$0.83/yr at $0.16/kWh) for 1 hr/day shower timers or 124.4 kWh/yr (~$19.90/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Loren Cook Company GCVF 100 (127.0 CFM).

## Why does rigid 6 in. diameter ducting protect Panasonic RG-C1315LA airflow?

Connecting Panasonic RG-C1315LA through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Panasonic RG-C1315LA performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic RG-C1315LA lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RG-C1315LA / Whisper Choice | PD ID 2405791 (Qualified 2022-02-18) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (143.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Panasonic RG-C1315LA?

Calculated coverage metrics translate Panasonic RG-C1315LA airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic RG-C1315LA

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 143 sq ft | 1 CFM/sq ft @ 143.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 127 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 93 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.2 kWh/yr (~$0.83/yr) | 14.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 124.4 kWh/yr (~$19.90/yr) | 14.2 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Panasonic RG-C1315LA?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**KORA SBF160DC-MS**](https://siematic-charleston.com/ventilation-fans/kora-sbf160dc-ms/) | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**Loren Cook Company GCVF 300**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-300/) | 167 / N/A CFM | 1.9 sones | 9.9 CFM/W | 8 x 6 in. rectangular |
| [**S&P PCD150**](https://siematic-charleston.com/ventilation-fans/s-p-pcd150/) | 150 / 159.6 CFM | Unpublished | 10.6 CFM/W | 6 in. diameter |
| [**Broan QTXE110150DC**](https://siematic-charleston.com/ventilation-fans/broan-qtxe110150dc/) | 150 / 147.8 CFM | Unpublished | 11.0 CFM/W | 6 in. diameter |

## Does Panasonic RG-C1315LA match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic RG-C1315LA percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Panasonic RG-C1315LA on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic RG-C1315LA carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 93 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 143.3 CFM net static output
- **Works well for:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Panasonic RG-C1315LA?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic RG-C1315LA.

### Will long attic ducting choke Panasonic RG-C1315LA capacity?

Because static drag at 0.25 in. w.g. lowers Panasonic RG-C1315LA from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Panasonic RG-C1315LA compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Panasonic RG-C1315LA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Panasonic RG-C1315LA consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Panasonic RG-C1315LA draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Panasonic RG-C1315LA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-C1315LA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic RG-C1315LA?

Panasonic RG-C1315LA features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic RG-C1315LA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-C1315LA's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Panasonic RG-C1315LA score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-C1315LA delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Panasonic RG-C1315LA?

Rule out Panasonic RG-C1315LA when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## Where can you explore more benchmarks around Panasonic RG-C1315LA?

Use the related reference pages and estimators below to cross-check Panasonic RG-C1315LA against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [S&P PCD150 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pcd150/)
- [S&P TD-125XS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-td-125xs/)
- [Panasonic RG-C1315A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-c1315a/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)