#  Panasonic RG-C811LHA Exhaust Fan Specifications

ENERGY STAR PD #2405789 · Bathroom/Utility Room · Qualified 2022-12-09

Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic RG-C811LHA delivers 110 CFM free-air (110.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 110 sq ft (8-ft height) or 98 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-C811LHA Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 110.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.9 CFM/W (#189/1,145)

- **Static Retention**: 100.3% @ 0.25"

- **Motor Draw**: 11.1 W (4.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic RG-C811LHA vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic RG-C811LHA (EPA filing PD #2405789) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.3 CFM out of 110 CFM (100.3% retention, 12.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU RG-C811LHA (series: Whisper Choice) (PD #2405789) certified since 2022-12-09. Lighting kit: Yes. At 9.9 CFM/W (#189 of 1,145, top 17.3% of 1,145 rated models, more efficient than 82.7% of rated models, 5.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.1 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 97.2 kWh/yr (~$15.55/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## Why does rigid 4 in. diameter ducting protect Panasonic RG-C811LHA airflow?

Connecting Panasonic RG-C811LHA through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Panasonic RG-C811LHA performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic RG-C811LHA lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RG-C811LHA / Whisper Choice | PD ID 2405789 (Qualified 2022-12-09) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (110.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Panasonic RG-C811LHA?

Calculated coverage metrics translate Panasonic RG-C811LHA airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic RG-C811LHA

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 110 sq ft | 1 CFM/sq ft @ 110.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 98 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 60 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.1 kWh/yr (~$0.66/yr) | 11.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 97.2 kWh/yr (~$15.55/yr) | 11.1 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Panasonic RG-C811LHA?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Does Panasonic RG-C811LHA match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic RG-C811LHA percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Panasonic RG-C811LHA?

Compare where Panasonic RG-C811LHA excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 60 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 110.3 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Panasonic RG-C811LHA?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic RG-C811LHA.

### Can Panasonic RG-C811LHA serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Panasonic RG-C811LHA supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Panasonic RG-C811LHA for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic RG-C811LHA lacks adequate reserve.

### How does Panasonic RG-C811LHA handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic RG-C811LHA yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Panasonic RG-C811LHA quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Panasonic RG-C811LHA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Panasonic RG-C811LHA energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Panasonic RG-C811LHA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-C811LHA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic RG-C811LHA?

Panasonic RG-C811LHA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic RG-C811LHA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-C811LHA's safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Panasonic RG-C811LHA?

Use the related reference pages and estimators below to cross-check Panasonic RG-C811LHA against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic RG-R811A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-r811a/)
- [Panasonic RG-R811A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-r811a-2405532/)
- [Panasonic RG-C811HA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-c811ha/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)