#  Panasonic RG-M79LA Exhaust Fan Specifications

ENERGY STAR PD #3543569 · Bathroom/Utility Room · Qualified 2024-05-03

Verified Specification Summary

Tested under HVI protocols, the Panasonic RG-M79LA exhaust unit achieves 90 CFM at 0.1 in. w.g. (77.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 4.1 CFM/W efficacy, covering standard baths up to 77 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-M79LA Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 90 / 77.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.1 CFM/W (#821/1,145)

- **Static Retention**: 86.1% @ 0.25"

- **Motor Draw**: 22.0 W (8.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic RG-M79LA vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic RG-M79LA (EPA filing PD #3543569) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 77.5 CFM out of 90 CFM (86.1% retention, 1.6 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Panasonic RG-M79LA (series: Whisper Mighty) under PD #3543569 (92 models registered, 2024-05-03). Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.0 watts, about 8.0 kWh/yr (~$1.28/yr at $0.16/kWh) for 1 hr/day shower timers or 192.7 kWh/yr (~$30.83/yr) continuously. Closest competing matches include Akicon AK1390N1-W/B/S (90.0 CFM) and Tech Drive TD-BF-11 (90.0 CFM).

## What attic duct routing preserves Panasonic RG-M79LA CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic RG-M79LA, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Panasonic RG-M79LA measure up on airflow and noise ratings?

Each row below breaks down Panasonic RG-M79LA certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RG-M79LA / Whisper Mighty | PD ID 3543569 (Qualified 2024-05-03) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (77.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How does ceiling height affect Panasonic RG-M79LA CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic RG-M79LA

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 77 sq ft | 1 CFM/sq ft @ 77.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 68 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 27 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.0 kWh/yr (~$1.28/yr) | 22.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 192.7 kWh/yr (~$30.83/yr) | 22.0 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Panasonic RG-M79LA?

Compare Panasonic RG-M79LA side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Akicon AK1390N1-W/B/S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n1-w-b-s/) | 90 / 67.4 CFM | 1.5 sones | 4.1 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-11**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-11/) | 90 / 82 CFM | 1.5 sones | 4.0 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-B**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-b/) | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-s/) | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-W**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-w/) | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |

## Can you size Panasonic RG-M79LA for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic RG-M79LA verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Panasonic RG-M79LA?

Match Panasonic RG-M79LA directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 77.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around ENERGY STAR sones up to 77 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Panasonic RG-M79LA?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic RG-M79LA.

### Where does Panasonic RG-M79LA run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic RG-M79LA.

### What happens to Panasonic RG-M79LA CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic RG-M79LA moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Panasonic RG-M79LA sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Panasonic RG-M79LA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Panasonic RG-M79LA cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic RG-M79LA 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Panasonic RG-M79LA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-M79LA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic RG-M79LA?

Panasonic RG-M79LA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic RG-M79LA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-M79LA's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Panasonic RG-M79LA ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-M79LA covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

## What neighboring pages and tools support Panasonic RG-M79LA?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Panasonic RG-M79LA.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan 744L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-744l/)
- [Delta GBR80H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-gbr80h/)
- [Panasonic RG-M79A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-m79a/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)