#  Panasonic RG-R811A Exhaust Fan Specifications

ENERGY STAR PD #2405531 · Bathroom/Utility Room · Qualified 2022-12-09

Verified Specification Summary

In EPA dataset 8dv7-nngq, Panasonic RG-R811A tests at 110 CFM free discharge (92.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 6.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 92 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-R811A Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 92.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 6.1 CFM/W (#448/1,145)

- **Static Retention**: 83.7% @ 0.25"

- **Motor Draw**: 18.0 W (6.6 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Panasonic RG-R811A vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic RG-R811A (EPA filing PD #2405531) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.1 CFM at 0.25 in. w.g. (83.7% retention, 4.0 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places RG-R811A (series: Whisper Remodel) (PD #2405531) among 92 Panasonic entries qualified through 2022-12-09. Lighting kit: No. At 6.1 CFM/W (#448 of 1,145, top 40.0% of 1,145 rated models, more efficient than 60.0% of rated models, 1.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.0 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 157.7 kWh/yr (~$25.23/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Tech Drive TD-BF-10 (110.0 CFM).

## Why avoid unvented attic termination with Panasonic RG-R811A?

Under ASHRAE 62.2 best practice, Panasonic RG-R811A needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Panasonic RG-R811A?

Before cutting ceiling drywall or sizing attic transitions for Panasonic RG-R811A, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Panasonic (92 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | RG-R811A / Whisper Remodel | PD ID 2405531 (Qualified 2022-12-09) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (92.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Panasonic RG-R811A?

Bathroom ventilation sizing below maps Panasonic RG-R811A motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Panasonic RG-R811A

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 157.7 kWh/yr (~$25.23/yr) | 18.0 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Panasonic RG-R811A in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Panasonic RG-R811A.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Tech Drive TD-BF-10**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-10-H**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-10-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TG-H**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tg-h/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |
| [**VENTECHLATION BPT14-24TGHS**](https://siematic-charleston.com/ventilation-fans/ventechlation-bpt14-24tghs/) | 110 / 99 CFM | 1.5 sones | 4.8 CFM/W | 4 in. diameter |

## What percentage of room demand does Panasonic RG-R811A cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Panasonic RG-R811A tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Panasonic RG-R811A on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Panasonic RG-R811A carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 92.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around ENERGY STAR sones up to 92 sq ft
- **Works well for:** Paired with rigid galvanized 3 in. diameter transition

## Where do official rules set limits for Panasonic RG-R811A?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Panasonic RG-R811A.

### Will long attic ducting choke Panasonic RG-R811A capacity?

Because static drag at 0.25 in. w.g. lowers Panasonic RG-R811A from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 3 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Panasonic RG-R811A compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Panasonic RG-R811A produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Panasonic RG-R811A consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Panasonic RG-R811A draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Panasonic RG-R811A pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-R811A's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Panasonic RG-R811A?

Panasonic RG-R811A features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Panasonic RG-R811A's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-R811A's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Panasonic RG-R811A score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-R811A delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Panasonic RG-R811A?

Rule out Panasonic RG-R811A when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## What related resources expand on Panasonic RG-R811A?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic RG-R811A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-r811a-2405532/)
- [Panasonic RG-R811HA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-r811ha/)
- [Panasonic RG-C811LHA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-rg-c811lha/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)