#  Pennbarry ZQ80-4" Exhaust Fan Specifications

ENERGY STAR PD #2322869 · Bathroom/Utility Room · Qualified 2018-06-20

Verified Specification Summary

Rated for 80 CFM open-air (unpublished 0.25 in. w.g. output), Pennbarry ZQ80-4" registers #24 of 607 in quietness (0.3 sones) and delivers 10.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 80 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Pennbarry ZQ80-4" Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / N/A CFM

- **Noise @ 0.1"**: 0.3 sones (#24/607)

- **Efficacy Rank**: 10.2 CFM/W (#179/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 7.8 W (2.8 kWh/yr)

- **Duct & Tier**: 8 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Pennbarry ZQ80-4" vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 80 CFM (#827 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Pennbarry maintains 2 active ENERGY STAR blowers; ZQ80-4" (series: Zephyr Quiet Ceiling Centrifugal Fan) (PD #2322869) gained qualification on 2018-06-20. Lighting kit: No. At 10.2 CFM/W (#179 of 1,145, top 16.2% of 1,145 rated models, more efficient than 83.8% of rated models, 5.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.8 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 68.3 kWh/yr (~$10.93/yr) continuously. Closest competing matches include Broan XB80 (80.0 CFM) and Broan XB80=XB00HwithXB80F (80.0 CFM).

## How does Pennbarry ZQ80-4" acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Pennbarry ZQ80-4" (0.3 sones).

## How do flex elbows choke Pennbarry ZQ80-4" at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 8 in. diameter metal pipe keeps Pennbarry ZQ80-4" moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Pennbarry ZQ80-4" meet residential exhaust fan code specs?

Inspect Pennbarry ZQ80-4" mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Pennbarry (2 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | ZQ80-4" / Zephyr Quiet Ceiling Centrifugal Fan | PD ID 2322869 (Qualified 2018-06-20) |
| **Duct Connection** | 8 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (80 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Pennbarry ZQ80-4" airflow output?

Annual electricity figures and room square-footage ceilings below reflect Pennbarry ZQ80-4" tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Pennbarry ZQ80-4"

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 80 sq ft | 1 CFM/sq ft @ 80 CFM |
| Tall Bath (9-ft Ceiling) | Up to 71 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 30 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.8 kWh/yr (~$0.45/yr) | 7.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 68.3 kWh/yr (~$10.93/yr) | 7.8 W x 8,760 hrs / 1,000 |

## Which competing models share Pennbarry ZQ80-4" airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan XB80**](https://siematic-charleston.com/ventilation-fans/broan-xb80-2248864/) | 80 / 80 CFM | 0.3 sones (Same) | 10.5 CFM/W | 4 in. diameter |
| [**Broan XB80=XB00HwithXB80F**](https://siematic-charleston.com/ventilation-fans/broan-xb80-xb00hwithxb80f-2333774/) | 80 / 80 CFM | 0.3 sones (Same) | 10.5 CFM/W | 4 in. diameter |
| [**Delta SIG80**](https://siematic-charleston.com/ventilation-fans/delta-sig80/) | 80 / 80.4 CFM | 0.3 sones (Same) | 9.6 CFM/W | 4 in. diameter |
| [**Delta 80HS**](https://siematic-charleston.com/ventilation-fans/delta-80hs/) | 80 / 59 CFM | 0.2 sones (-0.10) | 11.4 CFM/W | 4 in. diameter |
| [**Panasonic RG-S80LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-rg-s80lha/) | 80 / 83.9 CFM | 0.5 sones (+0.20) | 9.3 CFM/W | 4 in. diameter |

## How much airflow margin does Pennbarry ZQ80-4" give your bath?

Run a quick local room-volume check for Pennbarry ZQ80-4" by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Pennbarry ZQ80-4" fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Pennbarry ZQ80-4".

### Limitations & Who Should Skip

- Steam or walk-in tub room > 30 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 80 sq ft with 8-ft ceilings (71 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 8 in. diameter

## What should homeowners verify first about Pennbarry ZQ80-4"?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Pennbarry ZQ80-4".

### Which bathroom layouts should pick a larger blower than Pennbarry ZQ80-4"?

Do not force Pennbarry ZQ80-4" into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Pennbarry ZQ80-4" retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Pennbarry ZQ80-4" produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 8 in. diameter metal duct transitions.

### Will Pennbarry ZQ80-4" disturb adjacent bedrooms during night use?

Acoustic measurement places Pennbarry ZQ80-4" at 0.3 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Pennbarry ZQ80-4" continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Pennbarry ZQ80-4" draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Pennbarry ZQ80-4" pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Pennbarry ZQ80-4"'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Pennbarry ZQ80-4"?

Pennbarry ZQ80-4" features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Pennbarry ZQ80-4"'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Pennbarry ZQ80-4"'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Pennbarry ZQ80-4" code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Pennbarry ZQ80-4" clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## Which GradeMark tools pair best with Pennbarry ZQ80-4"?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Pennbarry ZQ80-4".

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Wintek BPT15B-80H2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt15b-80h2/)
- [Tech Drive TD-BF-06 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06/)
- [Nektra 33003852 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nektra-33003852/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)