Tested under HVI protocols, the PROJECT SOURCE 7140-70-PS exhaust unit achieves 70 CFM at 0.1 in. w.g. (51.7 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones) and delivers 3.3 CFM/W efficacy, covering standard baths up to 51 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside PROJECT SOURCE 7140-70-PS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 51.7 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.3 CFM/W (#1,077/1,145)

- **Static Retention**: 73.9% @ 0.25"

- **Motor Draw**: 21.2 W (7.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does PROJECT SOURCE 7140-70-PS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 51.7 CFM at 0.25 in. w.g. (73.9% retention, 13.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3626820 verifies 7140-70-PS (series: 7140-70-PS) under PROJECT SOURCE (5 listed models, qualified 2024-08-16). Lighting kit: No. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.2 watts, about 7.7 kWh/yr (~$1.23/yr at $0.16/kWh) for 1 hr/day shower timers or 185.7 kWh/yr (~$29.71/yr) continuously. Closest competing matches include HomeWerks Worldwide 7140-70-HW (70.0 CFM) and Air King BFQ75 (70.0 CFM).

## Where do PROJECT SOURCE 7140-70-PS sones rank across EPA ENERGY STAR fans?

Comparing PROJECT SOURCE 7140-70-PS (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves PROJECT SOURCE 7140-70-PS CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on PROJECT SOURCE 7140-70-PS, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does PROJECT SOURCE 7140-70-PS measure up on airflow and noise ratings?

Each row below breaks down PROJECT SOURCE 7140-70-PS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | PROJECT SOURCE (5 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7140-70-PS / 7140-70-PS | PD ID 3626820 (Qualified 2024-08-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (51.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect PROJECT SOURCE 7140-70-PS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for PROJECT SOURCE 7140-70-PS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 45 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.7 kWh/yr (~$1.23/yr) | 21.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 185.7 kWh/yr (~$29.71/yr) | 21.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against PROJECT SOURCE 7140-70-PS?

Compare PROJECT SOURCE 7140-70-PS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7140-70-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7140-70-hw/) | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**Air King BFQ75**](https://siematic-charleston.com/ventilation-fans/air-king-bfq75/) | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Air King WM70**](https://siematic-charleston.com/ventilation-fans/air-king-wm70/) | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Hampton Bay BF70HD**](https://siematic-charleston.com/ventilation-fans/hampton-bay-bf70hd/) | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Air King BFQL70**](https://siematic-charleston.com/ventilation-fans/air-king-bfql70/) | 70 / 58.6 CFM | 2.0 sones (Same) | 3.1 CFM/W | 4 in. diameter |

## Can you size PROJECT SOURCE 7140-70-PS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against PROJECT SOURCE 7140-70-PS verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying PROJECT SOURCE 7140-70-PS?

Match PROJECT SOURCE 7140-70-PS directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 51.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 2.0 sones up to 51 sq ft
- **Optimal use:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to PROJECT SOURCE 7140-70-PS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for PROJECT SOURCE 7140-70-PS.

### Where does PROJECT SOURCE 7140-70-PS sit on acoustic comfort for senior homeowners?

Measuring 2.0 sones, PROJECT SOURCE 7140-70-PS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does PROJECT SOURCE 7140-70-PS cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running PROJECT SOURCE 7140-70-PS 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can PROJECT SOURCE 7140-70-PS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from PROJECT SOURCE 7140-70-PS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing PROJECT SOURCE 7140-70-PS?

PROJECT SOURCE 7140-70-PS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change PROJECT SOURCE 7140-70-PS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing PROJECT SOURCE 7140-70-PS's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can PROJECT SOURCE 7140-70-PS ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), PROJECT SOURCE 7140-70-PS covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does PROJECT SOURCE 7140-70-PS run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with PROJECT SOURCE 7140-70-PS.

### What happens to PROJECT SOURCE 7140-70-PS CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, PROJECT SOURCE 7140-70-PS moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

## What neighboring pages and tools support PROJECT SOURCE 7140-70-PS?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around PROJECT SOURCE 7140-70-PS.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [PROJECT SOURCE 8771-70-PS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/project-source-8771-70-ps/)
- [PROJECT SOURCE 8772-70-PS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/project-source-8772-70-ps/)
- [HomeWerks Worldwide 7140-70-HW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7140-70-hw/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)