#  PROJECT SOURCE 8768-DS-PS Exhaust Fan Specifications

ENERGY STAR PD #4610274 · Bathroom/Utility Room · Qualified 2026-05-06

Verified Specification Summary

Certified by EPA ENERGY STAR, PROJECT SOURCE 8768-DS-PS delivers 80 CFM free-air (71.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 71 sq ft (8-ft height) or 63 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside PROJECT SOURCE 8768-DS-PS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 71.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.1 CFM/W (#292/1,145)

- **Static Retention**: 89.1% @ 0.25"

- **Motor Draw**: 8.8 W (3.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does PROJECT SOURCE 8768-DS-PS vs. 1,145-Model ENERGY STAR Benchmarks show?

PROJECT SOURCE 8768-DS-PS (EPA filing PD #4610274) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.3 CFM out of 80 CFM (89.1% retention, 1.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 8768-DS-PS (series: 8768-DS-PS) (PD #4610274) among 5 PROJECT SOURCE entries qualified through 2026-05-06. Lighting kit: Yes. At 9.1 CFM/W (#292 of 1,145, top 25.9% of 1,145 rated models, more efficient than 74.1% of rated models, 4.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.8 watts, about 3.2 kWh/yr (~$0.51/yr at $0.16/kWh) for 1 hr/day shower timers or 77.1 kWh/yr (~$12.34/yr) continuously. Closest competing matches include Delta VFB080B4A1-LVDC (80.0 CFM) and Delta ITG80 (80.0 CFM).

## Why does rigid 4 in. diameter ducting protect PROJECT SOURCE 8768-DS-PS airflow?

Connecting PROJECT SOURCE 8768-DS-PS through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify PROJECT SOURCE 8768-DS-PS performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for PROJECT SOURCE 8768-DS-PS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | PROJECT SOURCE (5 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 8768-DS-PS / 8768-DS-PS | PD ID 4610274 (Qualified 2026-05-06) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (71.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit PROJECT SOURCE 8768-DS-PS?

Calculated coverage metrics translate PROJECT SOURCE 8768-DS-PS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for PROJECT SOURCE 8768-DS-PS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.2 kWh/yr (~$0.51/yr) | 8.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 77.1 kWh/yr (~$12.34/yr) | 8.8 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to PROJECT SOURCE 8768-DS-PS?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VFB080B4A1-LVDC**](https://siematic-charleston.com/ventilation-fans/delta-vfb080b4a1-lvdc/) | 80 / 61.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG80**](https://siematic-charleston.com/ventilation-fans/delta-itg80/) | 80 / 68.3 CFM | 1.3 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 80F-LED**](https://siematic-charleston.com/ventilation-fans/delta-80f-led/) | 80 / 61.5 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| [**Delta 80RLED-ADJ**](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj/) | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| [**Delta 80RLED-ADJ-BN**](https://siematic-charleston.com/ventilation-fans/delta-80rled-adj-bn/) | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |

## Does PROJECT SOURCE 8768-DS-PS match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check PROJECT SOURCE 8768-DS-PS percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does PROJECT SOURCE 8768-DS-PS suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying PROJECT SOURCE 8768-DS-PS for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 21 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 71.3 CFM net static output
- **Best application:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for PROJECT SOURCE 8768-DS-PS?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around PROJECT SOURCE 8768-DS-PS.

### How many kWh per year does PROJECT SOURCE 8768-DS-PS add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, PROJECT SOURCE 8768-DS-PS averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can PROJECT SOURCE 8768-DS-PS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from PROJECT SOURCE 8768-DS-PS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing PROJECT SOURCE 8768-DS-PS?

PROJECT SOURCE 8768-DS-PS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change PROJECT SOURCE 8768-DS-PS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing PROJECT SOURCE 8768-DS-PS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does PROJECT SOURCE 8768-DS-PS pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), PROJECT SOURCE 8768-DS-PS easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install PROJECT SOURCE 8768-DS-PS in a bathroom remodel?

Avoid specifying PROJECT SOURCE 8768-DS-PS in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut PROJECT SOURCE 8768-DS-PS airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, PROJECT SOURCE 8768-DS-PS achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does PROJECT SOURCE 8768-DS-PS occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., PROJECT SOURCE 8768-DS-PS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## Where can you explore more benchmarks around PROJECT SOURCE 8768-DS-PS?

Use the related reference pages and estimators below to cross-check PROJECT SOURCE 8768-DS-PS against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVRL5080 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvrl5080/)
- [Delta SLM70D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm70d/)
- [Nutone 744RNL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-744rnl/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)