---
title: "PROJECT SOURCE 8772-70-PS Bath Fan (70 CFM, 2.0 Sone)"
url: https://siematic-charleston.com/ventilation-fans/project-source-8772-70-ps/
description: "ENERGY STAR specs for PROJECT SOURCE 8772-70-PS: 70 CFM, 2.0 sones (#522 of 607), 3.3 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  PROJECT SOURCE 8772-70-PS Exhaust Fan Specifications

ENERGY STAR PD #4613854 · Bathroom/Utility Room · Qualified 2026-04-22

Verified Specification Summary

In EPA dataset 8dv7-nngq, PROJECT SOURCE 8772-70-PS tests at 70 CFM free discharge (51.7 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 3.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 51 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside PROJECT SOURCE 8772-70-PS Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 51.7 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 3.3 CFM/W (#1,077/1,145)

- **Static Retention**: 73.9% @ 0.25"

- **Motor Draw**: 21.2 W (7.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does PROJECT SOURCE 8772-70-PS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 51.7 CFM at 0.25 in. w.g. (73.9% retention, 13.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: PROJECT SOURCE registers 5 certified models, with SKU 8772-70-PS (series: 8772-70-PS) (PD #4613854) certified since 2026-04-22. Lighting kit: No. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.2 watts, about 7.7 kWh/yr (~$1.23/yr at $0.16/kWh) for 1 hr/day shower timers or 185.7 kWh/yr (~$29.71/yr) continuously. Closest competing matches include HomeWerks Worldwide 7140-70-HW (70.0 CFM) and Air King BFQ75 (70.0 CFM).

## Does PROJECT SOURCE 8772-70-PS fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with PROJECT SOURCE 8772-70-PS at 2.0 sones.

## Why avoid unvented attic termination with PROJECT SOURCE 8772-70-PS?

Under ASHRAE 62.2 best practice, PROJECT SOURCE 8772-70-PS needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern PROJECT SOURCE 8772-70-PS?

Before cutting ceiling drywall or sizing attic transitions for PROJECT SOURCE 8772-70-PS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | PROJECT SOURCE (5 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 8772-70-PS / 8772-70-PS | PD ID 4613854 (Qualified 2026-04-22) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (51.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit PROJECT SOURCE 8772-70-PS?

Bathroom ventilation sizing below maps PROJECT SOURCE 8772-70-PS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for PROJECT SOURCE 8772-70-PS

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 51 sq ft | 1 CFM/sq ft @ 51.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 45 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.7 kWh/yr (~$1.23/yr) | 21.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 185.7 kWh/yr (~$29.71/yr) | 21.2 W x 8,760 hrs / 1,000 |

## What peer models sit nearest PROJECT SOURCE 8772-70-PS in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to PROJECT SOURCE 8772-70-PS.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7140-70-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7140-70-hw/) | 70 / 51.7 CFM | 2.0 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**Air King BFQ75**](https://siematic-charleston.com/ventilation-fans/air-king-bfq75/) | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Air King WM70**](https://siematic-charleston.com/ventilation-fans/air-king-wm70/) | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Hampton Bay BF70HD**](https://siematic-charleston.com/ventilation-fans/hampton-bay-bf70hd/) | 70 / 60.6 CFM | 2.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Air King BFQL70**](https://siematic-charleston.com/ventilation-fans/air-king-bfql70/) | 70 / 58.6 CFM | 2.0 sones (Same) | 3.1 CFM/W | 4 in. diameter |

## What percentage of room demand does PROJECT SOURCE 8772-70-PS cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against PROJECT SOURCE 8772-70-PS tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install PROJECT SOURCE 8772-70-PS in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting PROJECT SOURCE 8772-70-PS for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 51.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around 2.0 sones up to 51 sq ft
- **Primary match:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for PROJECT SOURCE 8772-70-PS?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing PROJECT SOURCE 8772-70-PS.

### How does PROJECT SOURCE 8772-70-PS sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, PROJECT SOURCE 8772-70-PS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define PROJECT SOURCE 8772-70-PS?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can PROJECT SOURCE 8772-70-PS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from PROJECT SOURCE 8772-70-PS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing PROJECT SOURCE 8772-70-PS?

PROJECT SOURCE 8772-70-PS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change PROJECT SOURCE 8772-70-PS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing PROJECT SOURCE 8772-70-PS's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does PROJECT SOURCE 8772-70-PS satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), PROJECT SOURCE 8772-70-PS clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is PROJECT SOURCE 8772-70-PS undersized or poorly matched for a bath renovation?

Skip PROJECT SOURCE 8772-70-PS if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check PROJECT SOURCE 8772-70-PS CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, PROJECT SOURCE 8772-70-PS registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

## What related resources expand on PROJECT SOURCE 8772-70-PS?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVL70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvl70/)
- [Revent RVLH70 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvlh70/)
- [PROJECT SOURCE 8771-70-PS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/project-source-8771-70-ps/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
